MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ijg.0000000000000538

Медицинская библиотека · Journal of glaucoma · 2017

Differences in Corneal Biomechanics in Nonpenetrating Deep Sclerectomy and Deep Sclerectomy Reconverted into Trabeculectomy.

Casado Alfonso, Cabarga Carmen, Pérez-Sarriegui Ane, Fuentemilla Enrique

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the differences in intraocular pressure (IOP) and in corneal biomechanics in eyes with uneventful nonpenetrating deep sclerectomy (NPDS) in 1 eye and with intended deep sclerectomy reconverted into trabeculectomy (RIT) in the fellow eye of the same patient.

PARTICIPANTS

Forty eyes of 20 patients with both types of glaucoma surgery and more than 6 months of follow-up, and 31 eyes of 50 controls.

METHODS

IOP was assessed with Goldmann applanation tonometry (GAT), ocular response analizer (ORA), and dynamic contour tonometer (DCT). Student t test for independent samples and a univariate generalized estimating equations model were used to analyze the results.

MAIN OUTCOME MEASURES: Overall, no significant differences were found between IOP of NPDS and RIT eyes when measured with 3 tonometers.

RESULTS

Although NPDS showed lower values of IOP measured with GAT and ORA, RIT presented lower IOP if DCT is the chosen tonometry. Biomechanically, NPDS eyes had higher corneal hysteresis (CH) and corneal resistance factor (CRF). When compared with control patients, eyes that underwent glaucoma surgery had lower IOP using GAT, DCT and ORA (P<0.001, 0.315, and 0.260, respectively), and lower CRF (P<0.001).

CONCLUSIONS

Eyes with NPDS tended to have higher values of CH and CRF and lower IOP than RIT eyes, as measured with 3 of 4 tonometry methods; these differences did not reach statistical significance.

Для цитирования: Casado Alfonso, Cabarga Carmen, Pérez-Sarriegui Ane, Fuentemilla Enrique. Differences in Corneal Biomechanics in Nonpenetrating Deep Sclerectomy and Deep Sclerectomy Reconverted into Trabeculectomy.. Journal of glaucoma. 2017. DOI: 10.1097/ijg.0000000000000538.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.