OBJECTIVE

To determine the value of galactomannan (GM) in bronchoalveolar lavage fluid (BALF) for diagnosing invasive pulmonary aspergillosis.

METHODS

According to the European Organization for Research and Treatment of Cancer / Invasive Fungal Infection Group (EORTC / IFICG) and the American Mycosis Research Group (MSG),and the American College of Infectious Diseases (IDSA) guidelines,295 patients with pulmonary aspergillosis (IPA) and high risk of invasive infections were divided into four groups: IPA group (42 cases),clinically diagnosed group (68 cases),suspected group (61 cases),and non-IPA group (124 cases). Their serum and BALF concentrations of GM were detected by enzyme-linked immunosorbent assay (ELISA).The clinically diagnosed and confirmed invasive pulmonary fungal infections (IPFI) were treated as golden standards (+). A GM value ≥ proposed threshold was deemed diagnostic test positive. Receiver operating characteristic (ROC) curves were drawn to determine the diagnostic efficiency of BALF GM assay for IPFI. The optimal cut-off point of BALF GM was determined using Youden index.

RESULTS

BALF GM had an area under the curve (AUC) of 0.932 in diagnosing IPFI,with 87.5% sensitivity, 96.7% specificity, 87.5% positive predictive value,and 96.7% negative predictive value when the BALF GM value was set at 1.5 ng/mL as the optimal cut-off point. Higher BALF and serum GM values were found in the confirmed IPA group,followed by the clinical diagnosed group compared with the non-IPA group ( P<0.05). The threshold value was set at 0.5 ng/mL for serum GM and 1.5 ng/mL for bronchoalveolar lavage GM. Higher positive rates were found in the confirmed IPA group and the clinical diagnosed group compared with the non-IPA group ( P<0.05). Serum GM appeared to have higher false positives and false negative rates.

CONCLUSION

BALF GM is a rapid and accurate indicator with high sensitivity and specificity for the early diagnosis of IPA.

Для цитирования: Deng Jin, Wu Si-Ying, Liu Ya, Ma Ying, Xie Yi, Chen Zhi-Xing, Dai Zhong-Qiu, Deng Jie-Lun, Kang Mei. [Galactomannan Tests of Bronchoalveolar Lavage Fluid for Diagnosing Invasive Pulmonary Aspergillosis].. Sichuan da xue xue bao. Yi xue ban = Journal of Sichuan University. Medical science edition. 2018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.