The safety and effectiveness of optometrist delivered laser peripheral iridotomy.

Swystun Alexander Geoffrey, Burton David, Edwards Alison, Alaghband Pouya

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Laser Peripheral Iridotomy (LPI) is a commonly performed procedure resulting in a reduction in the risk of progression to Acute Angle Closure and subsequent glaucoma. Whilst demand for LPI has varied over the previous 25 years, non-medical clinicians have been increasingly utilised in the delivery of ophthalmic laser procedures. There is, however, a paucity of safety and effectiveness of optometrist-performed LPI.

METHOD: This was a retrospective study. The success rate was determined by the presence of a patent LPI at the first appointment post-procedure. Adverse events were captured from electronic patient letters from the procedure until the first appointment post-procedure.

RESULTS

Two optometrists performed LPI on 105 eyes. Presence of a patent iridotomy was documented in 93% and 89% for optometrist one and two, respectively (n = 95). Transient adverse events were reported in four patients. The remaining 10 eyes underwent a redo LPI.

CONCLUSION

Optometrists delivered a safe and effective LPI service with low rate of adverse events and high success rates.

Для цитирования: Swystun Alexander Geoffrey, Burton David, Edwards Alison, Alaghband Pouya. The safety and effectiveness of optometrist delivered laser peripheral iridotomy.. Eye (London, England). 2026. DOI: 10.1038/s41433-025-04207-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.