Comparative analysis of fluidics and efficiency among different phaco-emulsifying machines employed for cataract surgery.

Boccuzzi Domenico, Napolitano Pasquale, Giannaccare Giuseppe, Taloni Andrea

Сравнительное исследованиеСтатьяНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

To analyze and compare the efficiency of three phaco-emulsifying machines by evaluating parameters related to fluidics and ultrasound time (UST). Pilot, prospective, observational, comparative study conducted at the "Mediterranea" Clinic Ophthalmology Operative Unit, Naples, Italy. A total of 145 consecutive cases of phacoemulsification were included in the study. Patients were randomized into 4 arms and operated using three phaco-emulsifying machines in 4 configurations equipped with three different infusion systems. The phaco machines were: (1) Centurion®, with and without the Active Sentry® handpiece (Alcon), (2) Stellaris Elite™ (Bauch & Lomb), and (3) Whitestar Signature® Pro (Johnson & Johnson). The primary outcomes were UST and fluid aspiration volume. Centurion, with and without Active Sentry, required less UST compared to other phaco machines (P < 0.001). Furthermore, Centurion required lower values of intraocular pressure (IOP) to complete the procedure and aspirated less fluid compared to the Stellaris Elite. No statistical differences in UST, aspirated fluid, and IOP have been found between Centurion and Centurion with Active Sentry. Centurion, with and without Active Sentry required lower UST and IOP for cataract removal compared to Stellaris Elite and Whitestar Signature Pro. Less fluid is necessary to complete the procedure compared to the Stellaris Elite.

Для цитирования: Boccuzzi Domenico, Napolitano Pasquale, Giannaccare Giuseppe, Taloni Andrea. Comparative analysis of fluidics and efficiency among different phaco-emulsifying machines employed for cataract surgery.. Scientific reports. 2025. DOI: 10.1038/s41598-025-27683-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.