m+Medelevator.RU
← Поиск публикаций
Clinical oncology (Royal College of Radiologists (Great Britain)) · 2023

Clinical Usefulness of Prostate-specific Membrane Antigen-ligand Positron Emission Tomography/Computed Tomography for the Detection of Prostate Cancer Biochemical Recurrence after Primary Radiation Therapy in Patients with Prostate-specific Antigen Below the Phoenix Threshold: Systematic Review and Meta-analysis.

МетаанализСистематический обзорСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Subiela J D, Gomis Sellés E, Maldonado A, Lopez Campos F, Aumatell Ovide J, Ajuria Illarramendi O, González-Padilla D A, Gajate P, Ortega Polledo L E, Alonso Y Gregorio S, Guerrero-Ramos F, Gómez Dos Santos V, Rodríguez-Patrón R, Calais J, Kishan A U, Burgos Revilla F J, Couñago F

Аннотация

AIMS: After primary radiotherapy, biochemical recurrence is defined according to the Phoenix criteria as a prostate-specific antigen (PSA) value >2 ng/ml relative to the nadir. Several studies have shown that prostate-specific membrane antigen (PSMA)-ligand positron emission tomography/computed tomography (PET/CT) can help in detecting recurrence in patients with low PSA values. This study aimed to assess the detection rate and patterns of PSMA-ligand PET/CT uptake in patients with suspected biochemical recurrence after primary radiotherapy and with PSA levels below the Phoenix threshold.

MATERIALS AND METHODS: The meta-analysis was carried out in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. Articles providing data on patients with suspected prostate cancer recurrence after primary radiotherapy with a PSA value below the Phoenix threshold and who underwent PSMA-ligand PET/CT were included. Quality assessment was carried out using the Quality Assessment of Diagnostic Accuracy Studies-2 tool (QUADAS-2).

RESULTS: In total, five studies were included, recruiting 909 patients (202 with PSA ≤2 ng/ml). The PSMA-ligand detection rate in the patients with ≤2 ng/ml ranged from 66 to 83%. The most frequent source of PSMA-ligand PET/CT uptake was local recurrence, followed by lymph node metastasis and bone metastasis. PSMA-ligand PET/CT uptake due to local-only recurrence was more likely in patients with PSA ≤2 ng/ml compared with PSA > 2 ng/ml: risk ratio 0.72 (95% confidence interval 0.58-0.89), P = 0.003. No significant differences were observed in the detection of PSMA-ligand uptake in other areas. Limitations include a lack of biopsy confirmation, cohort reports with small sample sizes and a potentially high risk of bias.

CONCLUSION: A significant detection of PSMA-ligand-avid disease was observed in patients with PSA levels below the Phoenix threshold. There was a higher likelihood of detecting local-only uptake when the PSA value was ≤2 ng/ml. The findings suggest that a critical review of the Phoenix criteria may be warranted in the era of PSMA-ligand PET/CT and highlight the need for further prospective trials.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты