INTRODUCTION

Tonsillectomy is one of the most common surgical procedures in Otorhinolaryngology and approximately 500 tonsillectomies are performed annually at the University Hospital of Vienna. Substantial postoperative bleeding is observed in 1.8% of cases, which is comparable to frequencies of 2-4% reported in other studies. Currently, routine pre-surgical coagulation investigations to predict bleeding status do not include the analysis of individual coagulation factors.

MATERIAL AND

METHODS

Within 2007 complete coagulation diagnostics were carried out in three patients presenting with recurrent (2-7 times) post-tonsillectomy hemorrhage but normal pre-surgical coagulation status parameters.

RESULTS

After the appearance of recurrent late bleeding, single factor diagnostic analysis revealed the causes to be factor XIIa deficiency, reduced factor XIIIa or von Willebrand disease. Recurrent late bleeding was stopped by the application of coagulation active plasma.

CONCLUSION

This study shows that, even if routine diagnostics show normal pre-surgical coagulation findings, the investigation of single factors in cases of post-surgical late bleeding may identify coagulation disorders allowing the application of tailored therapy. Including such analysis in pre-operative diagnostics could therefore significantly help to limit postoperative bleeding.

Для цитирования: Zumtobel Michaela, Frei Klemens. Occurrence of coagulation factor deficiency in post-tonsillectomy hemorrhage.. Wiener klinische Wochenschrift. 2011. DOI: 10.1007/s00508-011-1560-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.