MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/ijo.ijo_1387_23

Медицинская библиотека · Indian journal of ophthalmology · 2024

Comparative evaluation of biomechanical changes and aberration profile following accelerated collagen cross-linking using hypo-osmolar and iso-osmolar riboflavin: A prospective study.

Manumuraleekrishna, Asif Mohamed Ibrahime, Maharana Prafulla Kumar, Nagpal Ritu, Agarwal Tushar, Sinha Rajesh, Titiyal Jeewan Singh, Sharma Namrata

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the changes encountered in corneal biomechanics and aberration profile following accelerated corneal collagen cross-linking (CXL) using hypo-osmolar and iso-osmolar riboflavin in corneal thicknesses of <400 and >400 microns, respectively.

METHODS

This is a prospective, interventional, comparative study involving 100 eyes of 75 patients with progressive keratoconus. Eyes were divided into two groups based on corneal thickness: group 1 included eyes with a corneal thickness of <400 microns who underwent hypo-osmolar CXL, and group 2 included eyes with a corneal thickness of >400 microns who underwent iso-osmolar CXL. Corneal biomechanical and aberration profiles were evaluated and compared between groups.

RESULTS

In group 1, all higher-order aberrations (HOA) except secondary astigmatism significantly decreased from baseline; however, in group 2, only coma and trefoil decreased. The corneal resistance factor and corneal hysteresis significantly improved in both groups, which was significantly greater in group 2 than in group 1. The change in inverse radius, deformation amplitude, and tomographic biomechanical index was significantly improved in group 2 as compared to group 1.

CONCLUSION

Improvement in corrected distance visual acuity and decrease in HOA were significantly better in the hypo-osmolar CXL group; however, the improvement in biomechanical strength of the cornea was significantly better in the iso-osmolar group.

Для цитирования: Manumuraleekrishna, Asif Mohamed Ibrahime, Maharana Prafulla Kumar, Nagpal Ritu, Agarwal Tushar, Sinha Rajesh, Titiyal Jeewan Singh, Sharma Namrata. Comparative evaluation of biomechanical changes and aberration profile following accelerated collagen cross-linking using hypo-osmolar and iso-osmolar riboflavin: A prospective study.. Indian journal of ophthalmology. 2024. DOI: 10.4103/ijo.ijo_1387_23.