MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/1440-1630.12825

Медицинская библиотека · Australian occupational therapy journal · 2022

Construct validity, reliability, and responsiveness of the Wrist Position Sense Test for use in children with hemiplegic cerebral palsy.

Taylor Susan, Elliott Catherine, McLean Belinda, Parsons Richard, Falkmer Torbjorn, Carey Leeanne M, Blair Eve, Girdler Sonya

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

INTRODUCTION

We investigate the construct validity, test re-test reliability, and responsiveness of the Wrist Position Sense Test (WPST) for children with hemiplegic cerebral palsy (CP).

METHODS

Twenty-eight children with spastic hemiplegic CP [mean age 10.8 years; SD 2.4 years] and 39 typically developing (TD) children [mean age 11 years; SD 2.9 years] participated in a cross-sectional study to investigate construct validity and association with an upper limb activity measure, the Box and Block Test (BBT). Twenty-two TD children were tested at a second time-point to examine reliability. Test responsiveness was determined by random allocation of 17 children with CP to a treatment (n = 10) or control (n = 7) group with assessments completed at four time-points.

RESULTS

Significantly greater differences were observed in mean error of indicated wrist position (p < 0.01) in children with CP at baseline (M = 21.6°, SD = 21.6°) than in TD children (M = 12.8°, SD = 11.0°). Larger WPST errors were associated with poorer performance on the BBT (p < 0.01) indicating a substantial association, and there were no consistent differences between time-points indicating test re-test reliability within a TD population. The WPST demonstrated responsiveness to intervention with a statistically significant reduction in mean error following treatment (p < 0.001), not seen in the control group (p = 0.28).

CONCLUSION

The WPST demonstrated construct validity in this preliminary study. Scores were associated with an upper limb activity measure, and scores changed significantly following somatosensory training. These findings support further research and future psychometric investigation of the WPST in children with CP.

KEY POINTS FOR OCCUPATIONAL THERAPY: This study provides psychometric knowledge about the WPST tool The WPST shows promise as a discriminative measure with preliminary evidence of responsiveness and intra-rater reliability Until further testing, the WPST can be used cautiously in future research studies to measure wrist position sense.

Для цитирования: Taylor Susan, Elliott Catherine, McLean Belinda, Parsons Richard, Falkmer Torbjorn, Carey Leeanne M, Blair Eve, Girdler Sonya. Construct validity, reliability, and responsiveness of the Wrist Position Sense Test for use in children with hemiplegic cerebral palsy.. Australian occupational therapy journal. 2022. DOI: 10.1111/1440-1630.12825.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.