MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/tmi.13117

Медицинская библиотека · Tropical medicine & international health : TM & IH · 2018

Field and laboratory comparative evaluation of a LAMP assay for the diagnosis of urogenital schistosomiasis in Cubal, Central Angola.

Gandasegui Javier, Fernández-Soto Pedro, Dacal Elena, Rodríguez Esperanza, Saugar José María, Yepes Edward, Aznar-Ruiz-de-Alegría María Luisa, Espasa Mateu, Ninda Arlette, Bocanegra Cristina, Salvador Fernando, Sulleiro Elena, Moreno Milagros, Vicente Belén, López-Abán Julio, Muro Antonio

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the performance of Rapid-Heat LAMPellet assay in field conditions for diagnosis of urogenital schistosomiasis in an endemic area in Cubal, Angola, and to assess the reproducibility in a reference laboratory.

METHODS

A total of 172 urine samples from school-age children were tested for microhaematuria, microscopic detection of Schistosoma haematobium eggs and LAMP for DNA detection. Urine samples were stored in a basic equipped laboratory. Field-LAMP tests were performed with and without prior DNA extraction from urine samples, and the results were read by turbidity and by colour change. When field procedures were finished, samples were sent to a reference laboratory to be reanalysed by LAMP.

RESULTS

A total of 83 of 172 (48.3%) were positive for microhaematuria, 87/172 (50.6%) were microscopy-positive for S. haematobium eggs detection, and 127/172 (73.8%) showed LAMP-positive results for detecting S. haematobium using purified DNA and 109/172 (63.4%) without prior DNA extraction. MacNemar's test showed a statistical significant relation between LAMP results and microscopy-detected S. haematobium infections and microhaematuria (P < 0.001 in both cases), respectively. When samples of purified DNA were reanalysed in a reference laboratory in Spain using the same LAMP methodology, the overall reproducibility achieved 72.1%.

CONCLUSIONS

The ease of use, simplicity and feasibility demonstrated by LAMP assay in field conditions together with the acceptable level of reproducibility achieved in a reference laboratory support the use of LAMP assay as an effective test for molecular diagnosis of urogenital schistosomiasis in endemic remote areas.

Для цитирования: Gandasegui Javier, Fernández-Soto Pedro, Dacal Elena, Rodríguez Esperanza, Saugar José María, Yepes Edward, Aznar-Ruiz-de-Alegría María Luisa, Espasa Mateu, Ninda Arlette, Bocanegra Cristina, Salvador Fernando, Sulleiro Elena, Moreno Milagros, Vicente Belén, López-Abán Julio, Muro Antonio. Field and laboratory comparative evaluation of a LAMP assay for the diagnosis of urogenital schistosomiasis in Cubal, Central Angola.. Tropical medicine & international health : TM & IH. 2018. DOI: 10.1111/tmi.13117.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.