DOI 10.1016/s0385-8146(01)00102-x
Diagnosis of the elongated styloid process by three-dimensional computed tomography.
Аннотация
OBJECTIVE
To examine whether the styloid process can be imaged by three-dimensional computer tomography reconstruction (3-DCT) distinctly enough to be used for diagnosis, and whether the image findings are explanatory of the symptoms.
METHODS
We performed 3-DCT in four patients suspected to have elongated styloid process in our hospital. The apparatus we used was X-vigor (Toshiba), and the processing software was X-tension; the slicing thickness was 1.0 mm and the shifting speed of CT table was 1.0 mm per rotation. One hundred and twenty images were reconstructed for a view.
RESULTS
In all cases, the 3-DCT showed the exact full length of the styloid process. Two cases were diagnosed as elongation of the styloid process by 3-DCT and their image findings were explanatory of the symptoms. In other two cases, the 3-DCT showed no difference between the right and the left styloid processes, and thus the diagnosis of elongation of the styloid process had to be excluded.
CONCLUSION
We suggest that 3-DCT is useful for the diagnosis, explanation to patients and selection of treatment in some cases of elongated styloid process, but further study in more cases is required before we can fully confirm the utility.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.