BACKGROUND

A variety of autogenous and alloplastic materials have been used as subperiosteal implants to correct anophthalmic enophthalmos. Proplast II is a synthetic porous composite of Teflon polymer and alumina. Proplast II offers a number of advantages over other commonly used alloplastic materials such as silicone and polymethyl methacrylate. It is light, porous, resilient, malleable, and easy to shape. It can be readily sterilised after shaping. It has been found to integrate with the surrounding tissues, thereby minimising the risk of subsequent implant migration and extrusion.

METHODS

Proplast II was used as a subperiosteal implant in a total of 15 anophthalmic patients during the period June 1990 to March 1994. The indication for this procedure in all patients was poor orbital volume replacement despite the prior insertion of an adequately sized spherical socket implant.

RESULTS

The results were excellent with a good correction of preoperative upper eyelid sulcus deformity. There were no operative complications nor any serious postoperative complications. The implants were well tolerated.

CONCLUSION

Proplast II can be highly recommended for use as a subperiosteal implant.

Для цитирования: Shah S, Rhatigan M, Sampath R, Yeoman C, Sunderland S, Brammer R, Leatherbarrow B. Use of Proplast II as a subperiosteal implant for the correction of anophthalmic enophthalmos.. The British journal of ophthalmology. 1995. DOI: 10.1136/bjo.79.9.830.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.