BACKGROUND AND PURPOSE: This study was to evaluate the diagnostic value of improved motion-sensitized driven-equilibrium (iMSDE)-prepared 3D T1-weighted magnetic resonance imaging (MRI) (iMSDE-3DMRI) in intracranial vertebrobasilary dissection (VBD) and to compare iMSDE-3DMRI images with those obtained using 2D high-resolution (HR) MRI with respect to their diagnostic performance in VBD.

MATERIALS AND

METHODS

We retrospectively reviewed 105 lesions from 102 patients who underwent multimodal imaging and contrast-enhanced iMSDE-3DMRI (CE-iMSDE-3DMRI). The 2D-HRMRI protocol comprised four axial HR images. The CE-iMSDE-3DMRI images were reformatted in the axial, coronal, and sagittal planes. The 2D-HRMRI-based diagnosis was compared with the final diagnosis. The 2D-HRMRI and CE-iMSDE-3DMRI images were examined independently for the diagnosis performance of dissection.

RESULTS

VBD was confirmed in 66 lesions in 63 patients; 17 patients had confirmed atherosclerosis, and 22 had no lesions in the vertebrobasilar artery. Diagnostic performances of 2D-HRMRI (AUC, 0.839±0.04; sensitivity, 94.0; specificity, 79.5; diagnostic accuracy, 88.6) CE-iMSDE-3DMRI (AUC, 0.847±0.04; sensitivity, 84.8; specificity, 84.6; diagnostic accuracy, 84.7) and 2D-HRMRI+CE-iMSDE-3DMRI (AUC, 0.893±0.03; sensitivity, 97.0; specificity, 85.0; diagnostic accuracy, 92.5) were good. Comparisons of the diagnostic performance of 2D-HRMRI andCE-iMSDE-3DMRI showed that combined interpretation of 2D-HRMRI and iMSDE-3DMRI yields a significantly higher diagnostic performance than that of 2D-HRMRI (P=0.042).

CONCLUSIONS

CE-iMSDE-3DMRI showed good diagnostic performance for the diagnosis of intracranial VBD. These results suggest that CE-iMSDE-3DMRI can be used in combination with 2D-HRMRI for the diagnosis of intracranial VBD.

Для цитирования: Choi Jin Wook, Han Miran, Hong Ji Man, Lee Jin Soo, Kim Sun Yong, Kim Sam Soo. Feasibility of improved motion-sensitized driven-equilibrium (iMSDE) prepared 3D T1-weighted imaging in the diagnosis of vertebrobasilar artery dissection.. Journal of neuroradiology = Journal de neuroradiologie. 2017. DOI: 10.1016/j.neurad.2017.11.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.