MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jemermed.2021.07.002

Медицинская библиотека · The Journal of emergency medicine · 2021

Point-of-Care Ultrasound For Differentiating Ileocolic From Small Bowel-Small Bowel Intussusception.

Subramaniam Sathyaseelan, Chen Aaron E, Khwaja Asef, Rempell Rachel

СтатьяСистематический обзорПеревод пока не подготовлен

Аннотация

BACKGROUND

Intussusception is a common pediatric emergency. The two types of intussusception are ileocolic intussusception (ICI) and small bowel-small bowel intussusception (SB-SBI), and neither are easily distinguished clinically. ICI requires radiology personnel and potentially surgical assistance for its reduction. SB-SBI is managed expectantly, as many resolve spontaneously. Differentiating between ICI and SB-SBI through point-of-care ultrasound (POCUS) requires an understanding of their salient features. Identification of the correct type of intussusception immediately assists decision making and patient disposition.

OBJECTIVE OF THE REVIEW: Our objective was to provide guidance on POCUS technique for intussusception identification, and to review the ultrasound literature differentiating ICI from SB-SBI.

METHODS

We systematically searched 3 separate databases and gray literature to identify articles that met our criteria and assessed them for final review. The final articles were graded for quality using The National Institutes of Health quality assessment tool for observational cohort and cross-sectional studies.

RESULTS

A total of 858 articles were identified. Six articles were included in the final review. All studies were conducted in pediatric patients in different countries. Most were found to have a fair quality of evidence. The linear transducer is used when evaluating intussusception. Both ICI and SB-SBI are identified easily on POCUS, but they differ sonographically with respect to region within the abdomen, intussusception parameters, lymph nodes, and other salient features seen on real-time video.

CONCLUSIONS

ICI and SB-SBI can be identified and differentiated using several sonographic features. POCUS is capable of expeditiously aiding the emergency physician's decision making and disposition when managing intussusception.

Для цитирования: Subramaniam Sathyaseelan, Chen Aaron E, Khwaja Asef, Rempell Rachel. Point-of-Care Ultrasound For Differentiating Ileocolic From Small Bowel-Small Bowel Intussusception.. The Journal of emergency medicine. 2021. DOI: 10.1016/j.jemermed.2021.07.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.