MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.athoracsur.2011.10.057

Медицинская библиотека · The Annals of thoracic surgery · 2012

Assessment of the relationship between Contegra conduit size and early valvar insufficiency.

Gist Katja M, Mitchell Max B, Jaggers James, Campbell Dave N, Yu Jessica A, Landeck Bruce F

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Contegra bovine jugular vein (BJV) conduit results vary widely, and little attention has been directed at assessment of early conduit insufficiency. Conduit insufficiency is graded subjectively, and criteria vary. Several studies have used branch pulmonary artery flow reversal (BPAFR) to define severe conduit insufficiency. BJV valves are larger than human pulmonary valves of similar diameter. We hypothesize that anatomic differences between BJV and human pulmonary valves limit the use of BPAFR in the evaluation of BJV competence. Our purposes were to (1) assess the prevalence of early and 6-month BJV conduit insufficiency in our patients, (2) determine if conduit size affects BJV competence, and (3) determine if BPAFR is a specific discriminator of severe conduit insufficiency.

METHODS

We reviewed 135 BJV conduits. One cardiologist blinded to original reports reviewed postoperative and 6-month echocardiograms. Conduits were grouped by size: group 1, 12 to 14 mm (n=51), and group 2, 16 to 22 mm (n=84). Moderate or greater insufficiency was considered clinically significant.

RESULTS

Early conduit insufficiency was common in group 1 (37%) and rare in group 2 (5%, p<0.0001). After excluding conduits with significant insufficiency, BPAFR occurred in 18% (group 1, 27%; group 2, 13%; p=0.02). At follow-up, insufficiency worsened in group 1 but was stable in group 2.

CONCLUSIONS

Early conduit insufficiency is common and worsens with follow-up in small BJVs. Conduit insufficiency is limited in larger sizes and remains stable. BJV exhibits BPAFR commonly in the absence of significant conduit insufficiency. BPAFR should not be used as a primary criterion for grading insufficiency in BJV conduits.

Для цитирования: Gist Katja M, Mitchell Max B, Jaggers James, Campbell Dave N, Yu Jessica A, Landeck Bruce F. Assessment of the relationship between Contegra conduit size and early valvar insufficiency.. The Annals of thoracic surgery. 2012. DOI: 10.1016/j.athoracsur.2011.10.057.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.