DOI 10.1007/s10544-012-9670-7

Медицинская библиотека · Biomedical microdevices · 2012

Development of a micro-mechanical valve in a novel glaucoma implant.

Siewert Stefan, Schultze Christine, Schmidt Wolfram, Hinze Ulf, Chichkov Boris, Wree Andreas, Sternberg Katrin, Allemann Reto, Guthoff Rudolf, Schmitz Klaus-Peter

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

This paper describes methods for design, manufacturing and characterization of a micro-mechanical valve for a novel glaucoma implant. The implant is designed to drain aqueous humour from the anterior chamber of the eye into the suprachoroidal space in case of an elevated intraocular pressure (IOP). In contrast to any existing glaucoma drainage device (GDD), the valve mechanism is located in the anterior chamber and there, surrounded by aqueous humour, immune to fibrosis induced failure. For the prevention of hypotony the micro-mechanical valve is designed to open if the physiological pressure difference between the anterior chamber and the suprachoroidal space in the range of 0.8 mmHg to 3.7 mmHg is exceeded. In particular the work includes: (i) manufacturing and morphological characterization of polymer tubing, (ii) mechanical material testing as basis for (iii) the design of micro-mechanical valves using finite element analysis (FEA), (iv) manufacturing of microstent prototypes including micro-mechanical valves by femtosecond laser micromachining and (v) the experimental fluid-mechanical characterization of the manufactured microstent prototypes with regard to valve opening pressure. The considered materials polyurethane (PUR) and silicone (SIL) exhibit low elastic modulus and high extensibility. The unique valve design enables a low opening pressure of micro-mechanical valves. An ideal valve design for PUR and SIL with an experimentally determined opening pressure of 2 mmHg and 3.7 mmHg is identified. The presented valve approach is suitable for the inhibition of hypotony as a major limitation of today's GDD and will potentially improve the minimally invasive treatment of glaucoma.

Для цитирования: Siewert Stefan, Schultze Christine, Schmidt Wolfram, Hinze Ulf, Chichkov Boris, Wree Andreas, Sternberg Katrin, Allemann Reto, Guthoff Rudolf, Schmitz Klaus-Peter. Development of a micro-mechanical valve in a novel glaucoma implant.. Biomedical microdevices. 2012. DOI: 10.1007/s10544-012-9670-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.