MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2010.02.014

Медицинская библиотека · American journal of ophthalmology · 2010

Graft failure after penetrating keratoplasty in eyes with Ahmed valves.

Hollander David A, Giaconi Joann A, Holland Gary N, Yu Fei, Caprioli Joseph, Aldave Anthony J, Coleman Anne L, Casey Richard, Law Simon K, Mondino Bartly J

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To determine incidence and risk factors for graft failure following penetrating keratoplasty (PK) in eyes with Ahmed valves (AV).

DESIGN

Retrospective, observational cohort study.

METHODS

Patients who underwent PK after AV implantation (both performed at our institution through 2004) were studied. Intervals to graft failure (defined as either dysfunction [stromal thickening with retention of clarity] or decompensation [central microcystic edema or loss of clarity]) were analyzed using Kaplan-Meier technique. Risk factors for graft failure were analyzed using Cox proportional hazard models.

RESULTS

Included were 77 eyes (77 patients; first procedure 1993). Following PK, 40 eyes (52%) required increased numbers of glaucoma medications; 10 eyes (13%) required additional glaucoma drainage device(s). Graft failure at 1, 2, and 3 years was 42.4% (95% confidence interval: 32.0%-54.6%), 57.1% (45.6%-69.1%), and 59.1% (47.5%-71.2%), respectively. Prior PK (HR 2.38, P = .006) and stromal vessels (HR 2.90, P = .0005) were associated with increased risk of graft failure. Use of glaucoma medications (HR 0.27, P = .009) and evidence of lower intraocular pressures (IOP) during follow-up (excluding hypotony; HR 0.92, P = .010) were associated with reduced risk of graft failure. Endothelial rejection episodes were observed in 13 eyes (17%); however, rejection was not a risk factor for graft failure (P = .98).

CONCLUSIONS

Long-term survival of corneal grafts is poor in eyes with AV. The majority of graft failures are associated with progressive loss of endothelial function, without observed immunologic rejection. Despite the presence of an AV, escalation in glaucoma therapy often follows PK; graft failure may be related to poor IOP control.

Для цитирования: Hollander David A, Giaconi Joann A, Holland Gary N, Yu Fei, Caprioli Joseph, Aldave Anthony J, Coleman Anne L, Casey Richard, Law Simon K, Mondino Bartly J. Graft failure after penetrating keratoplasty in eyes with Ahmed valves.. American journal of ophthalmology. 2010. DOI: 10.1016/j.ajo.2010.02.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.