DOI 10.1097/ijg.0b013e3181d1d35d
Late bleb leak management with trabeculectomy shutdown, Baerveldt glaucoma device implantation, and titratable tube lumen size.
Аннотация
PURPOSE: To report a case of late subconjunctival bleb leak, and its management to preserve vision and achieve optimal pressure control in a patient with advanced glaucoma, a 3+ Seidel positive bleb leak, and hypotony maculopathy in the better-seeing eye.
DESIGN
Case Report.
METHODS
Shutdown of the earlier trabeculectomy site with a scleral graft was achieved before insertion of a 250-mm Baerveldt glaucoma device. An absorbable ligature was used around the tube to prevent early postoperative hypotony. Additional pressure control was obtained by using a permanent polypropylene ligature to decrease the effective lumen size after the resorbence of the vicryl ligature. This suture was left in a location that would be accessible to laser suture-lysis, or manual removal if necessary.
RESULTS
Intraocular pressure at 1 year postoperatively was 13 mm Hg on no medications with resolution of the macular folds and 3 lines of improvement of Snellen corrected distance visual acuity. The leak was completely resolved.
CONCLUSION
Excellent pressure control was achieved in the surgical management of a late onset bleb leak by shutting down the old trabeculectomy, and inserting a new Baerveldt tube shunt with an adjustable lumen size.