MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3760/cma.j.issn.0253-3758.2018.08.008

Медицинская библиотека · Zhonghua xin xue guan bing za zhi · 2018

[Efficacy and safety of three-dimensional electroanatomical mapping system for catheter ablation of paroxysmal supraventricular tachycardia in children].

Chen X J, Chen Y W, Dong J Z, Qiu C G, Tao H L, Han Z Y

СтатьяПеревод пока не подготовлен

Аннотация

Objective

To evaluate the efficacy and safety of three-dimensional electroanatomical mapping system for catheter ablation of paroxysmal supraventricular tachycardiain (PSVT) children.

Methods

Clinical data from 187 children with paroxysmal supraventricular tachycardia undergoing radiofrequency catheter ablation in our department between January 2012 and April 2016 were analyzed. Among the patients, 91 cases were treated with traditional two-dimensional X-ray radiofrequency ablation, 96 cases were treated with radiofrequency ablation guided by three-dimensional electroanatomical mapping system. Postoperative electrocardiogram and echocardiography follow-up was performed at 1, 3, 6, 12, and 24 months. The success rate, recurrence rate, complication rate, operation time and amount of X-ray exposure were compared between the two groups. Kaplan-Meier survival curve was used to analyze the PSVT-free survival rate of the patients between the 2 groups.

Results

The mean follow-up time was (739±92) days. The success rate (95.8%(92/96) vs. 94.5%(86/91), P=0.912), recurrence rate (5.4%(5/92) vs. 4.7%(4/86), P=0.807), complication rate (4.2%(4/96) vs. 5.5%(5/91), P=0.379), operation time ((73±31)min vs. (79±36)min, P=0.124) were similar between the two groups. However, X-ray exposure time ((8.1±2.9)min vs. (21.3±8.4)min, P=0.026), amount of X-ray ((23±11)mGy vs. (58±23)mGy, P=0.013) were significantly lower in the three-dimensional electroanatomical mapping system group than in the traditional two-dimensional X-ray radio frequency ablation group. PSVT-free survival rate was similar between the two groups (χ(2)=0.060, P=0.807) .

Conclusion

Three-dimensional electroanatomical mapping system is safe and effective for radiofrequency ablation of paroxysmal supraventricular tachycardia in children, and can significantly reduce the amount of radiation as compared to the traditional two-dimensional X-ray radiofrequency ablation.

Для цитирования: Chen X J, Chen Y W, Dong J Z, Qiu C G, Tao H L, Han Z Y. [Efficacy and safety of three-dimensional electroanatomical mapping system for catheter ablation of paroxysmal supraventricular tachycardia in children].. Zhonghua xin xue guan bing za zhi. 2018. DOI: 10.3760/cma.j.issn.0253-3758.2018.08.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.