BACKGROUND

Recently, most cases of hydrocephalus are related to obstruction. Accurate localization of the site of obstruction is crucial in determination of the treatment strategy.

PURPOSE: To describe the phase-contrast and 3D-DRIVE findings in cases of obstructive hydrocephalus in paediatric patients and to determine their functional and anatomical correlates.

MATERIAL AND

METHODS

Brain MRIs of 25 patients (2 months to 11 years) with obstructive hydrocephalus were retrospectively reviewed. Phase-contrast and 3D-DRIVE were performed to assess cerebrospinal (CSF) pathways through the aqueduct of Sylvius and subarachnoid spaces. In addition to flow velocity measurement at the aqueduct of Sylvius, functional and anatomical correlation was analysed at the level of aqueduct of Sylvius, infracerebellar CSF space and at the third ventriculostomy using Spearman's rank test.

RESULTS

Aqueduct of Sylvius was the most common site of obstruction (19 patients) either secondary to focal, multifocal or tubular stenosis, adhesions, or secondary to extrinsic compression. Functional and anatomical correlation was analysed in 58 regions revealing strong correlation (ro = 0.8, p < .001). Functional anatomical mismatch was found in nine regions. Flow velocity measurements revealed diminished flow in most of the cases with obstruction at the aqueduct and normal velocity in cases with obstruction proximal to aqueductal level, while accelerated flow was seen in cases with infra-aqeuductal obstruction.

CONCLUSION

Phase-contrast and 3D-DRIVE sequences are essential sequences in the diagnosis of hydrocephalus enabling perfect localization of the site of obstruction. Both sequences should be interpreted in conjunction to avoid false results. Velocity measurements through the aqueduct can help understand CSF hydrodynamics.

Для цитирования: Mohammad Shaimaa Abdelsattar, Osman Noha Mohamed, Khalil Reham M. Phase-contrast and three-dimensional driven equilibrium (3D-DRIVE) sequences in the assessment of paediatric obstructive hydrocephalus.. Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery. 2018. DOI: 10.1007/s00381-018-3850-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.