MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0165-0270(01)00409-5

Медицинская библиотека · Journal of neuroscience methods · 2001

Maintaining the cornea and the general physiological environment in visual neurophysiology experiments.

Metha A B, Crane A M, Rylander H G, Thomsen S L, Albrecht D G

СтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

Neurophysiologists have been investigating the responses of neurons in the visual system for the past half-century using monkeys and cats that are anesthetized and paralyzed, with the non-blinking eyelids open for prolonged periods of time. Impermeable plastic contact lenses have been used to prevent dehydration of the corneal epithelium, which would otherwise occur in minutes. Unfortunately, such lenses rapidly introduce a variety of abnormal states that lead to clouding of the cornea, degradation of the retinal image, and premature termination of the experiment. To extend the viability of such preparations, a new protocol for maintenance of corneal health has been developed. The protocol uses rigid gas permeable contact lenses designed to maximize gas transmission, rigorous sterile methods, and a variety of methods for sustaining and monitoring the overall physiology of the animal. The effectiveness of the protocol was evaluated clinically by ophthalmoscopy before, during, and after the experiments, which lasted 8-10 days. Histopathology and quantitative histology were performed on the corneas following the experiment. Our observations showed that this protocol permits continuous contact lens wear without adversely affecting the corneas. Thus, it is possible to collect data 24 h each day, for the entire duration of the experiment.

Для цитирования: Metha A B, Crane A M, Rylander H G, Thomsen S L, Albrecht D G. Maintaining the cornea and the general physiological environment in visual neurophysiology experiments.. Journal of neuroscience methods. 2001. DOI: 10.1016/s0165-0270(01)00409-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.