m+Medelevator.RU
← Поиск публикаций
Journal of cardiothoracic and vascular anesthesia · 2021

The Use of Factor Eight Inhibitor Bypass Activity (FEIBA) for the Treatment of Perioperative Hemorrhage in Left Ventricular Assist Device Implantation.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

O'Donnell Christian, Rodriguez Alexander J, Madhok Jai, Sharifi Husham, Wang Hanjay, O'Brien Connor G, Boyd Jack, Hiesinger William, Hsu Joe, Hill Charles C

Аннотация

OBJECTIVE: To test the hypothesis that factor eight inhibitor bypassing activity (FEIBA) can be used to control bleeding following left ventricular assist device (LVAD) implantation without increasing the 14-day composite thrombotic outcome of pump thrombus, ischemic cerebrovascular accidents, pulmonary embolism, and deep venous thrombosis.

DESIGN: Retrospective cohort study.

SETTING: Academic hospital.

PARTICIPANTS: Three hundred nineteen consecutive patients who underwent LVAD implantation (December 1, 2009 to December 30, 2018).

INTERVENTION: FEIBA administered to control perioperative hemorrhage.

MEASUREMENTS AND MAIN RESULTS: The 82 patients (25.7%) in the FEIBA cohort had more risk factors for perioperative hemorrhage, such as lower preoperative platelet count (169 ± 66 v 194 ± 68 × 103/mL, p = 0.004), prior cardiac surgery (36.6% v 21.9%, p = 0.008), and longer cardiopulmonary bypass (CPB) time (100.3 v 75.2 minutes, p = 0.001) than the 237 controls. After 16.6 units (95% CI: 14.3-18.9) of blood products were given, 992 units (95% CI: 821-1163) of FEIBA were required to control bleeding in the FEIBA cohort. Compared to the controls, there were no differences in the 14-day composite thrombotic outcome (11.0% v 7.6%, p = 0.343) or mortality rate (3.7% v 1.3%, p = 0.179). Multivariate logistical regression identified preoperative international normalized ratio (odds ratio [OR]: 1.30, 95% CI: 1.04-1.62) and CPB time (OR: 1.11, 95% CI: 1.02-1.20) as risk factors for 14-day thrombotic events, but FEIBA usage was not associated with an increased risk.

CONCLUSIONS: In this retrospective cohort study, the use of FEIBA (∼1,000 units, ∼13 units/kg) to control perioperative hemorrhage following LVAD implantation was not associated with increases in mortality or composite thrombotic outcome.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты