OBJECTIVE

To test the hypothesis that factor eight inhibitor bypassing activity (FEIBA) can be used to control bleeding following left ventricular assist device (LVAD) implantation without increasing the 14-day composite thrombotic outcome of pump thrombus, ischemic cerebrovascular accidents, pulmonary embolism, and deep venous thrombosis.

DESIGN

Retrospective cohort study.

SETTING

Academic hospital.

PARTICIPANTS

Three hundred nineteen consecutive patients who underwent LVAD implantation (December 1, 2009 to December 30, 2018).

INTERVENTION: FEIBA administered to control perioperative hemorrhage.

MEASUREMENTS AND MAIN

RESULTS

The 82 patients (25.7%) in the FEIBA cohort had more risk factors for perioperative hemorrhage, such as lower preoperative platelet count (169 ± 66 v 194 ± 68 × 103/mL, p = 0.004), prior cardiac surgery (36.6% v 21.9%, p = 0.008), and longer cardiopulmonary bypass (CPB) time (100.3 v 75.2 minutes, p = 0.001) than the 237 controls. After 16.6 units (95% CI: 14.3-18.9) of blood products were given, 992 units (95% CI: 821-1163) of FEIBA were required to control bleeding in the FEIBA cohort. Compared to the controls, there were no differences in the 14-day composite thrombotic outcome (11.0% v 7.6%, p = 0.343) or mortality rate (3.7% v 1.3%, p = 0.179). Multivariate logistical regression identified preoperative international normalized ratio (odds ratio [OR]: 1.30, 95% CI: 1.04-1.62) and CPB time (OR: 1.11, 95% CI: 1.02-1.20) as risk factors for 14-day thrombotic events, but FEIBA usage was not associated with an increased risk.

CONCLUSIONS

In this retrospective cohort study, the use of FEIBA (∼1,000 units, ∼13 units/kg) to control perioperative hemorrhage following LVAD implantation was not associated with increases in mortality or composite thrombotic outcome.

Для цитирования: O'Donnell Christian, Rodriguez Alexander J, Madhok Jai, Sharifi Husham, Wang Hanjay, O'Brien Connor G, Boyd Jack, Hiesinger William, Hsu Joe, Hill Charles C. The Use of Factor Eight Inhibitor Bypass Activity (FEIBA) for the Treatment of Perioperative Hemorrhage in Left Ventricular Assist Device Implantation.. Journal of cardiothoracic and vascular anesthesia. 2021. DOI: 10.1053/j.jvca.2021.04.030.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.