Optimal Low-Dose Synacthen Stimulation Test Sampling Time for Diagnosis of Adrenal Insufficiency Using Monoclonal Antibody Immunoassay.

Tosun Busra Gurpinar, Turan Serap, Haklar Goncagul, Bereket Abdullah, Guran Tulay

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

The low-dose synacthen stimulation test (LDSST) evaluates hypothalamo-pituitary-adrenal axis function. However, studies on the correlation between morning basal and stimulated cortisol concentrations using specific monoclonal antibody (mAb) immunoassays during LDSST are limited. To determine the best time-points and sampling approach for cortisol measurement using mAb immunoassay in children during LDSST.

METHODS

Morning basal and stimulated serum cortisol measurements in the LDSST were prospectively analyzed in 132 children (61 girls) with clinical suspicion of adrenal insufficiency (AI). Serum cortisol concentrations were assessed at 0, 30, 40, and 60th minutes during LDSST using mAb immunoassay. Simultaneously, morning basal cortisol levels in 119 patients were measured with both mAb immunoassay and liquid chromatography-mass spectrometry. AI was defined by a peak plasma cortisol concentration below 18 μg/dL (500 nmol/L).

RESULTS

AI was excluded in 80.3% (n = 106) of patients. The 40th minute showed the highest specificity (89.1%) for predicting LDSST outcomes with a single cortisol measurement. For two time-point measurements, the 40th and 60th minutes were significantly more sensitive than other possibilities (p < 0.001). A morning basal cortisol level below 6.5 μg/dL was identified as predictive of a failed LDSST result.

CONCLUSIONS

In LDSST, measurement of plasma cortisol at 40th and 60th minutes reduces the risk of false positivity. Single sampling at 40th minute yielded fewer false negatives than sampling at 30th or 60th minute.

Для цитирования: Tosun Busra Gurpinar, Turan Serap, Haklar Goncagul, Bereket Abdullah, Guran Tulay. Optimal Low-Dose Synacthen Stimulation Test Sampling Time for Diagnosis of Adrenal Insufficiency Using Monoclonal Antibody Immunoassay.. Hormone research in paediatrics. 2025. DOI: 10.1159/000544945.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.