MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1309/qwtqfga9fxn02yme

Медицинская библиотека · American journal of clinical pathology · 2007

Protein electrophoresis and immunoglobulin analysis in HIV-infected patients.

Konstantinopoulos Panagiotis A, Dezube Bruce J, Pantanowitz Liron, Horowitz Gary L, Beckwith Bruce A

СтатьяПеревод пока не подготовлен

Аннотация

We studied the prevalence and nature of immunoglobulin abnormalities in HIV-1-infected patients in the era of highly active antiretroviral therapy. Protein electrophoreses (PEP) were performed on and quantitative immunoglobulin levels obtained in samples from 320 consecutive HIV-1-infected patients. Samples with possible PEP abnormalities underwent immunofixation. The PEP pattern was normal in 83.8% of samples, 8.1% had subtle oligoclonal banding, and 4.4% had a low-concentration (<5% of total protein) monoclonal band. Hypogammaglobulinemia and polyclonal hypergammaglobulinemia accounted for 1.9% each. In multivariate analysis, younger age (odds ratio [OR], 1.06 with each decreasing year of life; 95% confidence interval [CI], 1.02-1.11; P = .016), female sex (OR, 2.4; 95% CI, 1.13-5.11; P = .02), viral load (OR, 1.50 with each increasing logarithmic viral load of 1.0; 95% CI, 1.14-1.98; P = .004), and CD4 cell count (> or =350 vs <350/microL [0.35 x 10(9)/L]) (OR, 2.71; 95% CI, 1.09-6.75; P = .032) were associated with monoclonal or oligoclonal banding. These results suggest that younger HIV-1-infected patients with a more robust immune system (higher CD4 cell count), which is stimulated by uncontrolled viremia, are most likely to have an augmented B-cell response to HIV infection. One manifestation of this B-cell response is low-concentration monoclonal banding in 4.4% of the patients studied.

Для цитирования: Konstantinopoulos Panagiotis A, Dezube Bruce J, Pantanowitz Liron, Horowitz Gary L, Beckwith Bruce A. Protein electrophoresis and immunoglobulin analysis in HIV-infected patients.. American journal of clinical pathology. 2007. DOI: 10.1309/qwtqfga9fxn02yme.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.