MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00204-020-02934-9

Медицинская библиотека · Archives of toxicology · 2020

The modified IL-8 Luc assay, an in vitro skin sensitisation test, can significantly improve the false-negative judgment of lipophilic sensitizers with logKow values > 3.5.

Kimura Yutaka, Fujimura Chizu, Aiba Setsuya

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

False-negative judgment due to poor chemical solubility is a problem with in vitro skin sensitisation tests. Water-insoluble chemicals are typically dissolved in DMSO in most sensitisation tests but precipitate when diluted with medium beyond their solubility in water. Such tests lack procedures to rule out false-negative judgments due to poor solubility. The IL-8 Luc assay (OECD442E) is unique in that if chemicals do not dissolve at 20 mg/mL in medium and have no effect on IL-8 luciferase activity (IL8LA), they are classified as indeterminate. The purpose of the present study was to reduce the number of indeterminate chemicals and improve assay performance. The IL-8 Luc assay can simultaneously examine glyceraldehyde 3-phosphate dehydrogenase luciferase activity (GAPLA) and IL8LA, and thus we examined the correlation between the reduction of GAPLA (defined as Inh-GAPLA) and the reduction of propidium iodide (PI)-excluding cells for three sensitizers and three non-sensitizers. We observed a significant correlation between luciferase activity driven by the GAPDH promoter of THP-G8 cells and the number of viable cells. Furthermore, chemicals providing an Inh-GAPLA value below 0.8 always reduced the ratio of PI-excluding cells to less than 0.6. Using the modified criteria, indeterminate chemicals are judged as negative if they provide Inh-GAPLA values below 0.8. This modification reduced the number of indeterminate chemicals and increased specificity, highlighting the unique advantage of the IL-8 Luc assay.

Для цитирования: Kimura Yutaka, Fujimura Chizu, Aiba Setsuya. The modified IL-8 Luc assay, an in vitro skin sensitisation test, can significantly improve the false-negative judgment of lipophilic sensitizers with logKow values > 3.5.. Archives of toxicology. 2020. DOI: 10.1007/s00204-020-02934-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.