MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.radonc.2020.10.032

Медицинская библиотека · Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2020

Towards homogenization of total body irradiation practices in pediatric patients across SIOPE affiliated centers. A survey by the SIOPE radiation oncology working group.

Hoeben Bianca A W, Pazos Montserrat, Albert Michael H, Seravalli Enrica, Bosman Mirjam E, Losert Christoph, Boterberg Tom, Manapov Farkhad, Ospovat Inna, Milla Soraya Mico, Abakay Candan Demiroz, Engellau Jacob, Kos Gregor, Supiot Stéphane, Bierings Marc, Janssens Geert O

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: To reduce relapse risk, Total Body Irradiation (TBI) is part of conditioning regimens for hematopoietic stem cell transplantation (HSCT) in pediatric acute leukemia. The study purpose was to evaluate clinical practices regarding TBI, such as fractionation, organ shielding and delivery techniques, among SIOPE affiliated radiotherapy centers.

METHODS

An electronic survey was sent out to 233 SIOPE affiliated centers, containing 57 questions about clinical practice of TBI. Surveys could be answered anonymously.

RESULTS

From over 25 countries, 82 responses were collected. For TBI-performing centers, 40/48 irradiated ≤10 pediatric patients annually (range: 1-2 to >25). Most indications concerned acute lymphoblastic leukemia (ALL) or acute myeloid leukemia (AML). Four different fractionation schedules were used, of which 12 Gy in 6 fractions was applied in 91% for ALL and 86% for AML. Dose reduction to the lungs, mostly to a mean dose of 8-10 Gy, was applied by 28/33 centers for ALL and 19/21 centers for AML, in contrast to much less applied dose reduction to the kidneys (7/33 ALL and 7/21 AML), thyroid (2/33 ALL and 2/21 AML), liver (4/33 ALL and 3/21 AML) and lenses (4/33 ALL and 4/21 AML). Conventional TBI techniques were used by 24/29 responding centers, while 5/29 used advanced optimized planning techniques.

CONCLUSION

Across SIOPE, there is a high level of uniformity in fractionation and use of lung shielding. Practices vary regarding other organs-at-risk shielding and implementation of advanced techniques. A SIOPE radiotherapy working group will be established to define international guidelines for pediatric TBI.

Для цитирования: Hoeben Bianca A W, Pazos Montserrat, Albert Michael H, Seravalli Enrica, Bosman Mirjam E, Losert Christoph, Boterberg Tom, Manapov Farkhad, Ospovat Inna, Milla Soraya Mico, Abakay Candan Demiroz, Engellau Jacob, Kos Gregor, Supiot Stéphane, Bierings Marc, Janssens Geert O. Towards homogenization of total body irradiation practices in pediatric patients across SIOPE affiliated centers. A survey by the SIOPE radiation oncology working group.. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. 2020. DOI: 10.1016/j.radonc.2020.10.032.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.