m+Medelevator.RU
← Поиск публикаций
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2013

Utility and safety of temporary pacing using active fixation leads and externalized re-usable permanent pacemakers after lead extraction.

Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kawata Hiro, Pretorius Victor, Phan Huy, Mulpuru Siva, Gadiyaram Varuna, Patel Jigar, Steltzner Dawna, Krummen David, Feld Gregory, Birgersdotter-Green Ulrika

Аннотация

AIMS: After extraction of an infected cardiac implantable electronic device (CIED) in a pacemaker-dependent patient, a temporary pacemaker wire may be required for long periods during antibiotic treatment. Loss of capture and under sensing are commonly observed over time with temporary pacemaker wires, and patient mobility is restricted. The use of an externalized permanent active-fixation pacemaker lead connected to a permanent pacemaker generator for temporary pacing may be beneficial because of improved lead stability, and greater patient mobility and comfort. The aim of this study was to investigate the efficacy and safety of a temporary permanent pacemaker (TPPM) system in patients undergoing transvenous lead extraction due to CIED infection.

METHODS AND RESULTS: Of 47 patients who underwent lead extraction due to CIED infection over a 2-year period at our centre, 23 were pacemaker dependent and underwent TPPM implantation. A permanent pacemaker lead was implanted in the right ventricle via the internal jugular vein and connected to a TPPM generator, which was secured externally at the base of the neck. The TPPM was used for a mean of 19.4 ± 11.9 days (median 18 days, range 3-45 days), without loss of capture or sensing failure in any patient. Twelve of 23 patients were discharged home or to a nursing facility with the TPPM until completion of antibiotic treatment and re-implantation of a new permanent pacemaker.

CONCLUSION: External TPPMs are safe and effective in patients requiring long-term pacing after infected CIED removal.