MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jbiomech.2026.113375

Медицинская библиотека · Journal of biomechanics · 2026

Tibiofemoral contact forces during walking with and without peak vertical ground reaction force feedback.

Jones Blake W, Willson John D, DeVita Paul, Wedge Ryan D

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The purpose of this study was to investigate whether individuals carrying vest-borne loads of 0%, 15%, and 30% body weight can decrease peak vertical ground reaction force (vGRF) when given peak vGRF feedback and examine if the gait adaptations induced by vGRF feedback decrease peak tibiofemoral joint (TFJ) contact force and impulse. Twenty-four participants walked without and with vGRF feedback at 1.4 m·s-1 with 0%, 15%, and 30% load added. They received feedback on the average peak vGRF for each leg in two-second epochs during each of the six conditions. Participants significantly decreased the second peak vGRF and vGRF impulse with feedback, but not the first peak vGRF. Due to an adopted crouched pattern, participants increased both first and second peak TFJ contact forces. vGRF and TFJ contact forces increased directly with increased load in both feedback conditions. vGRF force feedback represents an intuitive tool for modifying walking mechanics, but when employed to decrease ground reaction forces during load carriage in this study, it did not lead to decreased TFJ contact forces. Participants adopted a crouched gait that involved increased knee flexion and subsequent quadriceps demand, ultimately elevating TFJ loading. Future strategies aimed at decreasing joint load should consider targeting primary contributors of joint load, such as knee extensor moments, quadriceps force, or joint contact forces directly.

Для цитирования: Jones Blake W, Willson John D, DeVita Paul, Wedge Ryan D. Tibiofemoral contact forces during walking with and without peak vertical ground reaction force feedback.. Journal of biomechanics. 2026. DOI: 10.1016/j.jbiomech.2026.113375.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.