Cut-off values of neonatal lysosomal storage disease-related enzymes detected by tandem mass spectrometry.

Li Gaijie, Tian Liping, Guo Yuanfang, Li Yulin, Sun Meng, Zou Hui

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To establish cut-off values of lysosomal storage disease (LSD)-related enzymes by tandem mass spectrometry.

METHODS

A total of 26 689 newborns and 7 clinically confirmed LSD children underwent screening for LSDs (glycogen storage disease typeⅡ, Fabry disease, mucopolysaccharidosis type Ⅰ, Krabbe disease, Niemann-Pick disease A/B and Gaucher disease). The activities of LSD-related enzymes were detected by tandem mass spectrometry. The 20% of the median enzyme activity of each batch of acid β-glucocerebrosidase, acid sphingomyelinase, β-galactocerebroside, α- L-iduronidase and acid α-glucosidase, and the 30% of the median enzyme activity of α-galactosidase were taken as cut-off values of corresponding enzymes. The genetic diagnosis was performed in neonates whose enzyme activity was lower than 70% of the cut-off value.

RESULTS

The enzyme activities of 7 clinically confirmed cases were all lower than the cut-off values. Among 26 689 newborns, 142 cases (0.53%) were suspected positive for LSDs, including 25 cases of β-galactocerebroside deficiency, 1 case of α- L-iduronidase deficiency, 19 cases of α-galactosidase deficiency, and 97 cases of acid α-glucosidase deficiency. Eight infants were genetically diagnosed with LSDs, including 3 cases of glycogen storage disease type Ⅱ, 3 cases of Krabbe disease, and 2 cases of Fabry disease, with a positive predictive value of about 5.6%. Cut-off values ​​of the 6 LSD enzyme activities all showed a downward trend from March to August, and an upward trend from September to December. There was a statistically significant difference in LSD enzyme activity among different months ( P<0.05).

CONCLUSION

The established cut-off values of LSD-related enzyme activities detected by tandem mass spectrometry can be used for screening LSDs in neonates, and the enzyme activity would be affected by temperature and humidity.

Для цитирования: Li Gaijie, Tian Liping, Guo Yuanfang, Li Yulin, Sun Meng, Zou Hui. Cut-off values of neonatal lysosomal storage disease-related enzymes detected by tandem mass spectrometry.. Zhejiang da xue xue bao. Yi xue ban = Journal of Zhejiang University. Medical sciences. 2022. DOI: 10.3724/zdxbyxb-2022-0095.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.