MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7189/jogh.12.04088

Медицинская библиотека · Journal of global health · 2022

Associations between type of blood collection, analytical approach, mean haemoglobin and anaemia prevalence in population-based surveys: A systematic review and meta-analysis.

Stevens Gretchen A, Flores-Urrutia Monica C, Rogers Lisa M, Paciorek Christopher J, Rohner Fabian, Namaste Sorrel, Wirth James P

МетаанализСистематический обзорСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Previous studies have observed that haemoglobin concentrations can be affected by type of blood collection, analysis methods and device, and that near-in-time population-based surveys report substantially different anaemia prevalence. We investigated whether differences in mean haemoglobin or prevalence of anaemia between near-in-time surveys of the same population were associated with differences in type of blood collection or analytic approach to haemoglobin measurement.

METHODS

We systematically identified pairs of population-based surveys that measured haemoglobin in the same population of women of reproductive age (WRA) or preschool-aged children (PSC). Surveys were matched on geographic coverage, urban/rural place of residence, inclusion of pregnant women, time of data collection (within 18 months), and, to the extent feasible, age range. Differences in anaemia prevalence were presented graphically. Random-effects meta-analysis and meta-regression of difference in mean haemoglobin were carried out, with subgroups defined by comparison of type of blood collection and analytic approach within each survey pair.

RESULTS

We included 23 survey pairs from 17 countries for PSC and 17 survey pairs from 11 countries for WRA. Meta-regression indicates that surveys measuring haemoglobin with HemoCue® Hb 301 found higher haemoglobin concentrations than near-in-time surveys using HemoCue® Hb 201+ in non-pregnant women ((NPW); 5.8 g/L (95% confidence interval (CI) = 3.2-8.3) mean difference, n = 5 pairs) and PSC (4.3 g/L (1.4-7.2), n = 6). Surveys collecting venous blood found higher haemoglobin concentrations than near-in-time surveys collecting capillary blood in PSC (3.8 g/L (0.8-6.7), n = 8), but not NPW (0.4 g/L (-1.9-2.8), n = 9).

CONCLUSIONS

Because this study is observational, differences in haemoglobin concentrations in near-in-time surveys may be caused by other factors associated with choice of analytic approach or type of blood collected. The source or sources of differences should be clarified to improve use of surveys to prioritize and evaluate public health programs.

REGISTRATION: PROSPERO CRD42022296553.

Для цитирования: Stevens Gretchen A, Flores-Urrutia Monica C, Rogers Lisa M, Paciorek Christopher J, Rohner Fabian, Namaste Sorrel, Wirth James P. Associations between type of blood collection, analytical approach, mean haemoglobin and anaemia prevalence in population-based surveys: A systematic review and meta-analysis.. Journal of global health. 2022. DOI: 10.7189/jogh.12.04088.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.