MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00701-024-06165-0

Медицинская библиотека · Acta neurochirurgica · 2024

Intraoperative MRI without an intraoperative MRI suite: a workflow for glial tumor surgery.

Frisk Henrik, Persson Oscar, Fagerlund Michael, Jensdottir Margret, El-Hajj Victor Gabriel, Burström Gustav, Sunesson Annika, Kits Annika, Majing Tomas, Edström Erik, Kaijser Magnus, Elmi-Terander Adrian

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Intraoperative MRI (iMRI) has emerged as a useful tool in glioma surgery to safely improve the extent of resection. However, iMRI requires a dedicated operating room (OR) with an integrated MRI scanner solely for this purpose. Due to physical or economical restraints, this may not be feasible in all centers. The aim of this study was to investigate the feasibility of using a non-dedicated MRI scanner at the radiology department for iMRI and to describe the workflow with special focus on time expenditure and surgical implications.

METHODS

In total, 24 patients undergoing glioma surgery were included. When the resection was deemed completed, the wound was temporarily closed, and the patient, under general anesthesia, was transferred to the radiology department for iMRI, which was performed using a dedicated protocol on 1.5 or 3 T scanners. After performing iMRI the patient was returned to the OR for additional tumor resection or final wound closure. All procedural times, timestamps, and adverse events were recorded.

RESULT: The median time from the decision to initiate iMRI until reopening of the wound after scanning was 68 (52-104) minutes. Residual tumors were found on iMRI in 13 patients (54%). There were no adverse events during the surgeries, transfers, transportations, or iMRI-examinations. There were no wound-related complications or infections in the postoperative period or at follow-up. There were no readmissions within 30 or 90 days due to any complication.

CONCLUSION

Performing intraoperative MRI using an MRI located outside the OR department was feasible and safe with no adverse events. It did not require more time than previously reported data for dedicated iMRI scanners. This could be a viable alternative in centers without access to a dedicated iMRI suite.

Для цитирования: Frisk Henrik, Persson Oscar, Fagerlund Michael, Jensdottir Margret, El-Hajj Victor Gabriel, Burström Gustav, Sunesson Annika, Kits Annika, Majing Tomas, Edström Erik, Kaijser Magnus, Elmi-Terander Adrian. Intraoperative MRI without an intraoperative MRI suite: a workflow for glial tumor surgery.. Acta neurochirurgica. 2024. DOI: 10.1007/s00701-024-06165-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.