MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0335841

Медицинская библиотека · PloS one · 2025

Infectious complications in children on ventricular assist device: A single-center retrospective cohort study.

Seiler Raphael, Speckmann Nehle, Hernandez Toro Camilo Jose, Huscher Dörte, Berger Felix, Photiadis Joachim, Cho Mi-Young, Schmitt Katharina, Miera Oliver

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Mechanical circulatory support with ventricular assist device (VAD) is a life-saving therapy in children with end-stage heart failure. Infections are a major problem in VAD-therapy and may lead to significant morbidity and mortality. The aim of the study was to evaluate possible risk factors for superficial percutaneous lead/canula infections (SI) and to determine their impact on overall outcome during VAD-therapy.

METHODS

Single center, retrospective analysis of infectious complications in 70 consecutive children supported on a VAD (58 Berlin Heart EXCOR Pediatric pulsatile flow pump and 12 Heartware continuous flow pump). Cox proportional hazard models with SI, bloodstream infections, and stroke as outcome, as well as a competing risk model for device weaning, death, and heart transplantation were used to identify risk factors in the study population.

RESULTS

SI were documented in twelve out of 70 children (17%). The event rate for SI was 5.86 per 100 patient months [95%CI 3.03-10.23] with a median time to SI of 109 days [IQR 66-163]. The occurrence of SI was mostly in patients with longer support times while the underlying diagnosis and previous thoracotomies had no impact on the number of SI. Further, children older than three years of age had a higher risk for SI (HR 2.67; 95% CI 1.09-6.57, p = 0.032). SI were not associated with the risk of bloodstream infections (HR 1.27; 95%CI 0.44-3.67, p = 0.656) or death (HR 0.32; 95% CI 0.06-1.80, p = 0.194).

CONCLUSIONS

SI occurred frequently during VAD therapy in children, without leading to a higher rate of bloodstream infections or mortality. Further, being above three years of age at VAD implantation was associated with increased risk to develop SI.

Для цитирования: Seiler Raphael, Speckmann Nehle, Hernandez Toro Camilo Jose, Huscher Dörte, Berger Felix, Photiadis Joachim, Cho Mi-Young, Schmitt Katharina, Miera Oliver. Infectious complications in children on ventricular assist device: A single-center retrospective cohort study.. PloS one. 2025. DOI: 10.1371/journal.pone.0335841.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.