Long-term inflammatory outcome after placement of a novel two-piece dental implant in a dog model experimental peri-implantitis.

Liat Chaushu, Haim Tal

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: Evaluate the inflammatory outcome of a two-piece novel titanium dental implant (test article) vs. a one- piece titanium dental implant (control article) inducing experimental peri-implantitis in a dog model.

MATERIALS &

METHODS

A novel, two-piece pre-assembled implant with a 0.2-thickness sleeve in its coronal 4.2 mm part was developed (Test article). Ligature-induced experimental periimplantitis model was applied, followed by decontamination and bone grafting in seven dogs. Four groups were assessed according to decontamination and resurfacing protocol: E1 (Experimental 1): test article- sleeve removed, mechanical and chemical decontamination, new rough surface non-threaded sleeve was inserted; E2 (Experimental 2): test article- sleeve removed, mechanical and chemical decontamination, test article remained denuded presenting a turned non-threaded surface; C1 (Control 1): sleeve remained, mechanical and chemical decontamination in test article, original rough surface, non-threaded sleeve; C2 (Control 2): control article cleaning, mechanical and chemical decontamination of original rough surface, threaded implant. Buccolingual and mesiodistal sections were prepared for each site. Resin qualitative and semi-quantitative histopathologic inflammatory parameters were analyzed.

RESULTS

Group C1 showed statistically significant highest signs of residual long-term inflammation, followed by groups E1, and C2. Group E2 displayed the lowest local inflammation. Mesio/Distal aspects displayed increased long-term inflammatory infiltrate albeit not statistically significant.

CONCLUSIONS

Within the limits of the present study, it may be concluded that - (1) The decontamination procedure is more effective in a commercial one-piece vs. a two-piece dental implant. (2) Mechanical and chemical decontamination outcome is insufficient. Resurfacing improves the decontamination outcome. (3) Decontamination of the turned surface is superior to the rough surface.

CLINICAL RELEVANCE: When choosing the most appropriate dental implant for individuals with a high risk for peri-implant disease, a one-piece dental implant with a turned crestal surface is preferable. Once occurring, the control of peri-implant disease inflammation may be more successful. Decontamination is usually not enough. Resurfacing is highly recommended if possible.

Для цитирования: Liat Chaushu, Haim Tal. Long-term inflammatory outcome after placement of a novel two-piece dental implant in a dog model experimental peri-implantitis.. Clinical oral investigations. 2024. DOI: 10.1007/s00784-024-05907-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.