MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0161-6420(93)31617-9

Медицинская библиотека · Ophthalmology · 1993

The Teller acuity card procedure. Three testers in a clinical setting.

Quinn G E, Berlin J A, James M

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

PURPOSE: The Teller acuity card procedure provides a quantitative measure of grating acuity in infants and young children and has been used in clinical and laboratory settings. The purpose of this study is to address the influence of the individual testers in a clinical setting. The authors report a comparison of acuity results obtained by three well-trained, experienced testers in a busy hospital-based clinical practice.

METHODS

Three different testers (A, B, C) performed 971 consecutive acuity assessments using the Teller acuity card procedure on 570 patients. The testers used similar techniques and adaptations, depending on clinical need. Diagnostic categories include nystagmus, aphakia, strabismus, glaucoma, retinopathy of prematurity (ROP), ptosis, optic nerve abnormalities, etc. Patients ranged in age from 2 weeks to 17 years (mean +/- standard deviation, 23 +/- 20 months).

RESULTS

When each patient was represented only once, A tested 144 patients; B, 251; and C, 175. The geometric mean right eye acuity scores of A were 3.00 cycles/degree (cy/deg) (0.34 octaves, standard error [SE]; n = 134); B, 4.05 cy/deg (0.20 octave, SE; n = 225); and C, 3.71 cy/deg (0.30 octave, SE; n = 163). An analysis of covariance showed a significant difference in the mean log scores across testers (P = 0.02 adjusted for both age and diagnosis). Age was a strong predictor of acuity (P = 0.0001), and the interactions between tester and age and tester and diagnosis were not significant. The geometric mean left eye acuity scores for A were 2.86 cy/deg (0.33 octave, SE; n = 132); B, 3.46 cy/deg (0.23 octave, SE; n = 218); and C, 3.32 cy/deg (0.30 octave, SE; n = 160). The differences for left eyes among testers were not significant (P = 0.37 adjusted for age and diagnosis).

CONCLUSIONS

These results suggest that the tester may influence the acuity results measured by the Teller acuity card procedure in a clinical setting. Evaluation of interobserver reliability in clinical subjects should be a high priority of further work using the Teller acuity card procedure.

Для цитирования: Quinn G E, Berlin J A, James M. The Teller acuity card procedure. Three testers in a clinical setting.. Ophthalmology. 1993. DOI: 10.1016/s0161-6420(93)31617-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.