MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1001/archophthalmol.2009.111

Медицинская библиотека · Archives of ophthalmology (Chicago, Ill. : 1960) · 2009

Use of a continuous probability scale to display visual field damage.

Wall Michael, Johnson Chris A, Kardon Randy H, Crabb David P

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To derive and display the percentile score (1st-99th percentile) at each perimetric location of a standard automated perimetry test to determine whether this technique will uncover patterns of loss not visible in standard (StatPac) probability maps.

METHODS

We computed continuous scale probability plots of data collected from testing 305 visually healthy participants with standard automated perimetry (24-2 Swedish interactive thresholding algorithm). The age-corrected thresholds were sorted by sensitivity at each visual field location. Percentiles were derived in single increments from the 1st to the 99th. We displayed the percentiles as a color scale and then interpreted visual field plots from healthy control subjects and patients with visual system disorders.

RESULTS

Added information was achieved for identifying patterns of visual loss by using the 5th- to 20th-percentile range in conjunction with the lower range below the 5th percentile that is typically used. The extent of contiguous regional defects appeared larger using this method. Healthy control subjects often have threshold results within the 5th- to 20th-percentile range, but these test locations usually appeared randomly spaced rather than in contiguous patterns commonly seen in patients at the border of visual field defects.

CONCLUSION

Continuous scale probability plots are a potentially useful adjunct for interpretation of perimetry results.

Для цитирования: Wall Michael, Johnson Chris A, Kardon Randy H, Crabb David P. Use of a continuous probability scale to display visual field damage.. Archives of ophthalmology (Chicago, Ill. : 1960). 2009. DOI: 10.1001/archophthalmol.2009.111.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.