DOI 10.1097/wno.0b013e31818e3cd7

Медицинская библиотека · Journal of neuro-ophthalmology : the official journal of the North American Neuro-Ophthalmology Society · 2008

Perimetry while moving the eyes: implications for the variability of visual field defects.

Toepfer Armin, Kasten Erich, Guenther Tobias, Sabel Bernhard A

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

In standard perimetry, subjects fixate so that saccades are reduced and testing precision is increased. However, because vision in daily life requires eye movements, it is appropriate to assess visual fields during eye movement.

METHODS

Perimetry was carried out in 8 healthy subjects and in 16 patients with visual field defects under conditions of a stable and moving fixation spot. Eye movements were simultaneously recorded with an eye tracker. Outcome measures included stimulus detection, variability of visual field border, and saccade amplitudes.

RESULTS

Perimetric performance during stable fixation was comparable to that during eye movement. All subjects showed 92%-96% correct detections of the fixation controls and a stable and comparable blind spot position in the stable and moving fixation spot conditions. The eye tracker revealed that 97% of the time the eyes were positioned within +/-1 from fixation.

CONCLUSIONS

Visual fields obtained by perimetry while moving the eyes is comparable to standard perimetry in which a stable fixation spot minimizes eye movements.

Для цитирования: Toepfer Armin, Kasten Erich, Guenther Tobias, Sabel Bernhard A. Perimetry while moving the eyes: implications for the variability of visual field defects.. Journal of neuro-ophthalmology : the official journal of the North American Neuro-Ophthalmology Society. 2008. DOI: 10.1097/wno.0b013e31818e3cd7.

Предметные рубрики MeSH