Electrochemical capillary-driven microfluidic DNA sensor for HIV-1 and HCV coinfection analysis.

Chittuam Khanut, Jampasa Sakda, Vilaivan Tirayut, Tangkijvanich Pisit, Chuaypen Natthaya, Avihingsanon Anchalee, Sain Mohini, Panraksa Yosita, Chailapakul Orawon

СтатьяПеревод в очереди

Аннотация

Electrochemical DNA sensors can be operated in either static or flow-based detection schemes. In static schemes, manual washing steps are still necessary, resulting in a tedious and time-consuming process. In contrast, in flow-based electrochemical sensors, the current response is collected when the solution flows through the electrode continuously. However, the drawback of such a flow system is the low sensitivity due to the limited time for the interaction between the capturing element and the target. Herein, we propose a novel electrochemical capillary-driven microfluidic DNA sensor to combine the advantages of static and flow-based electrochemical detection systems into a single device by incorporating burst valve technology. The microfluidic device with a two-electrode configuration was applied for the simultaneous detection of two different DNA markers, human immunodeficiency virus-1 (HIV-1) and hepatitis C virus (HCV) cDNA, via the specific interaction between pyrrolidinyl peptide nucleic acids (PNA) probes and the DNA target. The integrated system, while requiring a small sample volume (7 μL for each sample loading port) and less analysis time, achieved good performance in terms of the limits of detection (LOD) (3SDblank/slope) and quantification (LOQ) (10SDblank/slope) at 1.45 nM and 4.79 nM for HIV and 1.20 nM and 3.96 nM for HCV, respectively. The simultaneous detection of HIV-1 and HCV cDNA prepared from human blood samples showed results that are in complete agreement with the RT‒PCR assay. The results qualify this platform as a promising alternative for the analysis of either HIV-1/HCV or coinfection that can be easily adapted for other clinically important nucleic acid-based markers.

Для цитирования: Chittuam Khanut, Jampasa Sakda, Vilaivan Tirayut, Tangkijvanich Pisit, Chuaypen Natthaya, Avihingsanon Anchalee, Sain Mohini, Panraksa Yosita, Chailapakul Orawon. Electrochemical capillary-driven microfluidic DNA sensor for HIV-1 and HCV coinfection analysis.. Analytica chimica acta. 2023. DOI: 10.1016/j.aca.2023.341257.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.