MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.vaa.2021.04.011

Медицинская библиотека · Veterinary anaesthesia and analgesia · 2021

Investigation of biomarkers for impending fluid overload in a feline acute haemorrhage-resuscitation model.

Zeiler Gareth E, Dzikiti Brighton T, Kamerman Peter, Pohlin Friederike, Buck Roxanne K, Fuller Andrea

СтатьяRandomized Controlled Trial, VeterinaryПеревод пока не подготовлен

Аннотация

OBJECTIVE

To determine biomarkers for impending fluid overload during intravenous fluid administration in a feline haemorrhage-resuscitation model.

STUDY

DESIGN

Randomized crossover study.

ANIMALS: A group of six domestic cats (mean age and weight: 21 months; 4.9 kg, respectively).

METHODS

The cats underwent three treatments, 2 months apart. They were anaesthetized and instrumented to measure a range of physiological, blood gas, haematological and biochemical variables over time. Samples were taken during a health check, before haemorrhage, after haemorrhage and then at 30 minute intervals during fluid resuscitation and 24 hours later. The three treatments were: 1) control, sham haemorrhage and resuscitation; 2) lactated Ringer's solution (LRS); and 3) 6% tetrastarch 130/0.4 (Vol) where the cats underwent a controlled haemorrhage then resuscitation by administering LRS and Vol at 60 and 20 mL kg-1 hour-1, respectively, for 120 minutes. Fluid overload was identified by nasal discharge and radiographic evidence. Biomarkers were variables that exceeded the reference interval for cats during treatment. Potential biomarkers were analysed using receiver operating characteristic curves (p < 0.05).

RESULTS

Mean ± standard deviation total blood loss was 10.2 ± 2.3, 29.3 ± 9.0 and 29.1 ± 6.3 mL kg-1 for control, LRS and Vol, respectively. The total volume of LRS and Vol administered was 120 and 40 mL kg-1, respectively. Haematocrit, albumin, magnesium, chloride-to-sodium ratio and sodium-chloride difference were identified as potential biomarkers. These variables exceeded the reference intervals from 30 minutes of resuscitation onwards. A chloride-to-sodium ratio > 0.84 was the most sensitive (90%) and specific (75%) of all potential biomarkers.

CONCLUSIONS AND CLINICAL RELEVANCE: Changes in physiological variables, haematocrit and albumin were poor biomarkers of impending fluid overload compared with electrolytes. Finding the ideal biomarker to identify impending fluid overload of commonly used intravenous fluids should improve the safety of their administration in cats.

Для цитирования: Zeiler Gareth E, Dzikiti Brighton T, Kamerman Peter, Pohlin Friederike, Buck Roxanne K, Fuller Andrea. Investigation of biomarkers for impending fluid overload in a feline acute haemorrhage-resuscitation model.. Veterinary anaesthesia and analgesia. 2021. DOI: 10.1016/j.vaa.2021.04.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.