MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-013-2916-9

Медицинская библиотека · European radiology · 2013

Simultaneous dual-isotope SPECT/CT with (99m)Tc- and (111)In-labelled albumin microspheres in treatment planning for SIRT.

Palmowski Moritz, Goedicke Andreas, Vogg Andreas, Christ Götz, Mühlenbruch Georg, Kaiser Hans J, Günther Rolf W, Kuhl Christiane K, Mottaghy Felix M, Behrendt Florian F

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To investigate simultaneous dual-isotope SPECT/CT with two differently radioisotope-labelled albumin-microsphere fractions for treatment planning of hepatic radioembolisation.

METHODS

In addition to (99m)Technetium-labelled albumin microspheres (commercially available), we performed labelling with (111)Indium. Binding stability of (111)Indium-labelled microspheres was tested in vitro and in vivo in mice. Simultaneous dual-isotope SPECT/CT imaging was validated in an anthropomorphic torso phantom; subsequently, dual-isotope SPECT/CT was performed under in-vivo conditions in pigs (n = 3) that underwent transarterial injection of (99m)Technetium- and (111)Indium-labelled microspheres in the liver (right and left hepatic artery, respectively), in both kidneys and in the gluteal musculature. In total, n = 18 transarterial injections were performed.

RESULTS

In-vitro testing and in-vivo studies in mice documented high binding stability for both (99m)Technetium-labelled and (111)Indium-labelled microsphere fractions. In phantom studies, simultaneous dual-isotope SPECT/CT enabled reliable separation of both isotopes. In pigs, the identified deposition of both isotopes could be accurately matched with intended injection targets (100 %, 18/18 intended injection sites). Furthermore, an incidental deposition of (99m)Technetium-labelled microspheres in the stomach could be correlated to the test injection into a right hepatic artery.

CONCLUSION

Simultaneous dual-isotope SPECT/CT after transarterial injection with (99m)Technetium- and (111)Indium-labelled microspheres is feasible. Thus, it may offer additional, valuable information compared to single (99m)Technetium-labelled albumin examinations.

KEY POINTS: • Simultaneous dual-isotope SPECT/CT with (111) In- and (99m) Tc-labelled albumin microspheres is feasible. • Differentiation of two microsphere fractions after transarterial injection is possible. • The origin of an extra-hepatic microsphere deposition can be correlated to the corresponding artery. • This technique could reduce the setup time for selective internal radiation treatment.

Для цитирования: Palmowski Moritz, Goedicke Andreas, Vogg Andreas, Christ Götz, Mühlenbruch Georg, Kaiser Hans J, Günther Rolf W, Kuhl Christiane K, Mottaghy Felix M, Behrendt Florian F. Simultaneous dual-isotope SPECT/CT with (99m)Tc- and (111)In-labelled albumin microspheres in treatment planning for SIRT.. European radiology. 2013. DOI: 10.1007/s00330-013-2916-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.