DOI 10.1016/j.jtha.2024.07.024
Sensitivity and specificity of strategies to identify patients with hemostasis abnormalities leading to an increased risk of bleeding before scheduled intervention: the Hemorisk study.
Аннотация
BACKGROUND
Preoperative identification of patients with hemostasis abnormalities leading to an increased bleeding risk is based on routine hemostasis tests: prothrombin time (PT), activated partial thromboplastin time (APTT), and platelet count. Because of their low predictive performance, guidelines recommend replacing them with structured bleeding risk questionnaires, but none is validated in this population.
OBJECTIVES
To assess the diagnostic accuracy of 3 strategies, performed at the preanesthesia visit before scheduled interventions, and to identify patients with hemostasis abnormalities leading to an increased bleeding risk
METHODS
A multicenter study was performed in 7 French academic hospitals, involving patients scheduled for surgical intervention, without antiplatelet/anticoagulant treatment. The 3 strategies consisted of 1-a structured screening questionnaire; 2-PT, APTT, and platelet count ordered in selected patients; and 3-systematic PT, APTT, and platelet count. The reference standard comprised von Willebrand factor activity/antigen, factor (F)VIII, FIX, FXI, platelet function analyzer, and, when required, FII, FV, FX, and FVII and hemostasis consultation.
RESULTS
Eighteen (1.2%) of 1484 patients had a hemostasis abnormality leading to an increased bleeding risk according to reference standard. In the overall cohort, sensitivity of the questionnaire-based strategy was 50% (95% CI, 26%-74%; specificity, 87% [95% CI, 85%-88%]); sensitivity was 0% (95% CI, 0%-41%) in men vs 82% (95% CI, 48%-98%) in women. For selective routine tests, sensitivity was 33% (95% CI, 13%-59%) and specificity 97% (95% CI, 96%-98%). Corresponding values for systematic routine tests were 44% (95% CI, 22%-69%) and 93% (95% CI, 91%-94%).
CONCLUSION
Sensitivity was low for all 3 strategies investigated. The structured screening questionnaire had clinically acceptable diagnostic accuracy only in women.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.