MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/jcp-2024-209542

Медицинская библиотека · Journal of clinical pathology · 2025

F8 variants and their genotype-phenotype correlations in Thai patients with haemophilia A: a nationwide multicentre study.

Trirut Chayanit, Sosothikul Darintr, Ittiwut Rungnapa, Ittiwut Chupong, Pongsewalak Sureeporn, Songthawee Natsaruth, Natesirinilkul Rungrote, Banjerdlak Pallapa, Na Songkhla Pokpong, Komvilaisak Patcharee, Moonla Chatphatai, Suphapeetiporn Kanya

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

AIMS: Analysis of the F8 gene helps predict the risk of developing factor VIII (FVIII) inhibitors and the depth of phenotype in haemophilia A (HA) patients. Since data in Southeast Asian countries remain scarce, we aim to study F8 variation correlated with HA phenotypes in Thailand.

METHODS

Thai patients with HA were enrolled from seven haemophilia treatment centres during 2022-2023. Using peripheral blood DNA, inverse shifting-polymerase chain reaction (IS-PCR) for F8-intron 22 inversion (Inv22) and F8-intron 1 inversion (Inv1) was performed. Whole exome sequencing (WES) was explored in cases without Inv22/Inv1.

RESULTS

Of 124 patients with HA, 91.9% were detected with a causative F8 variant, including Inv22 (30.6%), Inv1 (1.6%), missense (23.4%), nonsense (16.9%) and small insertion/deletion (16.1%) mutations. Inv22, small insertion/deletion and nonsense were associated with severe HA, compared with missense variants, by the ORs of 13.9 (95% CI, 4.2 to 56.7), 14.7 (95% CI, 3.4 to 104.7) and 15.6 (95% CI, 3.6 to 110.2), respectively. While nonsense variants affecting the light chain increased the risk of developing FVIII inhibitors (OR, 6.8; 95% CI, 1.5 to 32.6) compared with the low-risk (small insertion/deletion, missense and splice-site) variants. Twelve patients (9.7%) harboured novel F8 variants, comprising five missense (p.Pro540Leu, p.Ser564Pro, p.Leu668Pro, p.Ala1721Glu, p.His2024Pro), five small insertion/deletion (p.Val502SerfsTer13, p.Ile522PhefsTer13, p.Phe992LysfsTer11, p.Leu1223PhefsTer18, c.6427_6429+3delATGGTA) and one nonsense mutations (p.Glu1292Ter).

CONCLUSIONS

IS-PCR followed by WES successfully assesses F8 alterations in most HA cases. With several unique variants, severe HA in Thailand is considerably caused by Inv22, small insertion/deletion and nonsense, whereas missense variants are more responsible for nonsevere HA phenotypes.

Для цитирования: Trirut Chayanit, Sosothikul Darintr, Ittiwut Rungnapa, Ittiwut Chupong, Pongsewalak Sureeporn, Songthawee Natsaruth, Natesirinilkul Rungrote, Banjerdlak Pallapa, Na Songkhla Pokpong, Komvilaisak Patcharee, Moonla Chatphatai, Suphapeetiporn Kanya. F8 variants and their genotype-phenotype correlations in Thai patients with haemophilia A: a nationwide multicentre study.. Journal of clinical pathology. 2025. DOI: 10.1136/jcp-2024-209542.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.