BACKGROUND

Peristomal dermatitis is a common problem in patients with ostomies that is a source of considerable morbidity. Irritant contact dermatitis is most common, but allergic contact dermatitis can also occur. Because of the lack of published reports on patch testing for this indication, we undertook a retrospective study of patch testing results in patients with suspected peristomal allergic contact dermatitis.

OBJECTIVE

We sought to describe our patch testing experience with patients referred with peristomal dermatitis.

METHODS

This was a retrospective review of medical records of patients with ostomies and peristomal dermatitis who underwent patch testing in the Mayo Clinic Departments of Dermatology in Jacksonville, FL; Rochester, MN; and Scottsdale, AZ, during a 10-year period (2000-2010).

RESULTS

Ten patients with peristomal dermatitis were referred for patch testing (6 in Minnesota, 2 in Florida, and 2 in Arizona). Patients were patch tested to the materials used in their stoma devices, to the standard series, and in some cases to supplemental series. All 10 had at least one allergic patch test reaction, most commonly to stoma paste (3 of 10 patients).

LIMITATIONS: Retrospective nature of study via chart review is a limitation.

CONCLUSION

Patch testing is a useful tool for identification of allergens in patients with peristomal dermatitis.

Для цитирования: Landis Megan N, Keeling James H, Yiannias James A, Richardson Donna M, Nordberg Linehan Diane L, Davis Mark D P. Results of patch testing in 10 patients with peristomal dermatitis.. Journal of the American Academy of Dermatology. 2011. DOI: 10.1016/j.jaad.2011.07.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.