JACC. Clinical electrophysiology · 2018

Dual-Site Ventricular Pacing in Patients With Fontan Physiology and Heart Block: Does it Mitigate the Detrimental Effects of Single-Site Ventricular Pacing?

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

O'Leary Edward T, Gauvreau Kimberlee, Alexander Mark E, Banka Puja, Bezzerides Vassilios J, Fynn-Thompson Francis, Triedman John K, Walsh Edward P, Mah Douglas Y

Аннотация

OBJECTIVES: This study sought to determine the long-term effect of dual-site ventricular pacing (i.e., cardiac resynchronization therapy [CRT]) versus single-site pacing in patients with Fontan physiology and high-grade atrioventricular block (AVB).

BACKGROUND: Chronic single-site ventricular pacing in Fontan patients is associated with significant morbidity and mortality.

METHODS: The study conducted a retrospective review of all Fontan patients with high-grade AVB who received pacemakers at a single institution between 1990 and 2016 with follow-up of 12 months or greater. The primary study outcome was a composite of death or heart transplantation.

RESULTS: Nineteen patients received CRT devices and 43 patients received single-site ventricular pacemakers (SVPMs), with a median follow-up of 4.9 years (range 1.1 to 11.3 years) and 10.4 years (range 1.1 to 26.8 years), respectively. One (5.3%) CRT patient and 11 (25.6%) SVPM patients reached the composite endpoint of death or transplant (odds ratio: 0.16; 95% confidence interval: 0.02 to 1.36; p = 0.09). Kaplan-Meier analysis showed similar rates of freedom from death or transplant between the 2 study groups over a 5-year follow-up period (p = 0.08). The proportion of SVPM patients with abnormal ventricular systolic function before device implantation (9.5%) and at follow-up (33.3%) significantly increased (p=0.009). The CRT cohort had less change in their ventricular function (42.1% before device implant, 36.8% at follow-up; p = 1.00); however, a Kaplan-Meier analysis over a 5-year follow-up period found no difference in the presence of abnormal ventricular systolic function between groups (p = 0.27).

CONCLUSIONS: There was no significant difference in long-term outcomes between Fontan patients who were single- or dual-site paced for high-grade AVB.

Предметные рубрики MeSH