Circulation. Cardiovascular interventions · 2013
Outcomes of transcatheter and surgical aortic valve replacement in high-risk patients with aortic stenosis and left ventricular dysfunction: results from the Placement of Aortic Transcatheter Valves (PARTNER) trial (cohort A).
СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Elmariah Sammy, Palacios Igor F, McAndrew Thomas, Hueter Irene, Inglessis Ignacio, Baker Joshua N, Kodali Susheel, Leon Martin B, Svensson Lars, Pibarot Philippe, Douglas Pamela S, Fearon William F, Kirtane Ajay J, Maniar Hersh S, Passeri Jonathan J, PARTNER Investigators
Аннотация
BACKGROUND: The Placement of Aortic Transcatheter Valves (PARTNER) trial demonstrated similar survival after transcatheter and surgical aortic valve replacement (TAVR and SAVR, respectively) in high-risk patients with symptomatic, severe aortic stenosis. The aim of this study was to evaluate the effect of left ventricular (LV) dysfunction on clinical outcomes after TAVR and SAVR and the impact of aortic valve replacement technique on LV function.
METHODS AND RESULTS: The PARTNER trial randomized high-risk patients with severe aortic stenosis to TAVR or SAVR. Patients were stratified by the presence of LV ejection fraction (LVEF) <50%. All-cause mortality was similar for TAVR and SAVR at 30-days and 1 year regardless of baseline LV function and valve replacement technique. In patients with LV dysfunction, mean LVEF increased from 35.7±8.5% to 48.6±11.3% (P<0.0001) 1 year after TAVR and from 38.0±8.0% to 50.1±10.8% after SAVR (P<0.0001). Higher baseline LVEF (odds ratio, 0.90 [95% confidence interval, 0.86, 0.95]; P<0.0001) and previous permanent pacemaker (odds ratio, 0.34 [95% confidence interval, 0.15, 0.81]) were independently associated with reduced likelihood of ≥10% absolute LVEF improvement by 30 days; higher mean aortic valve gradient was associated with increased odds of LVEF improvement (odds ratio, 1.04 per 1 mm Hg [95% confidence interval, 1.01, 1.08]). Failure to improve LVEF by 30 days was associated with adverse 1-year outcomes after TAVR but not SAVR.
CONCLUSIONS: In high-risk patients with severe aortic stenosis and LV dysfunction, mortality rates and LV functional recovery were comparable between valve replacement techniques. TAVR is a feasible alternative for patients with symptomatic severe aortic stenosis and LV dysfunction who are at high risk for SAVR.
CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00530894.
METHODS AND RESULTS: The PARTNER trial randomized high-risk patients with severe aortic stenosis to TAVR or SAVR. Patients were stratified by the presence of LV ejection fraction (LVEF) <50%. All-cause mortality was similar for TAVR and SAVR at 30-days and 1 year regardless of baseline LV function and valve replacement technique. In patients with LV dysfunction, mean LVEF increased from 35.7±8.5% to 48.6±11.3% (P<0.0001) 1 year after TAVR and from 38.0±8.0% to 50.1±10.8% after SAVR (P<0.0001). Higher baseline LVEF (odds ratio, 0.90 [95% confidence interval, 0.86, 0.95]; P<0.0001) and previous permanent pacemaker (odds ratio, 0.34 [95% confidence interval, 0.15, 0.81]) were independently associated with reduced likelihood of ≥10% absolute LVEF improvement by 30 days; higher mean aortic valve gradient was associated with increased odds of LVEF improvement (odds ratio, 1.04 per 1 mm Hg [95% confidence interval, 1.01, 1.08]). Failure to improve LVEF by 30 days was associated with adverse 1-year outcomes after TAVR but not SAVR.
CONCLUSIONS: In high-risk patients with severe aortic stenosis and LV dysfunction, mortality rates and LV functional recovery were comparable between valve replacement techniques. TAVR is a feasible alternative for patients with symptomatic severe aortic stenosis and LV dysfunction who are at high risk for SAVR.
CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00530894.
Предметные рубрики MeSH
AgedAged, 80 and overAortic ValveAortic Valve StenosisCardiac CatheterizationCardiac Surgical ProceduresComorbidityFemaleFollow-Up StudiesHeart Valve ProsthesisHeart Valve Prosthesis ImplantationHumansKaplan-Meier EstimateMalePacemaker, ArtificialRecovery of FunctionRisk FactorsStroke VolumeSurvival RateTreatment OutcomeVentricular Dysfunction, Left