JACC. Cardiovascular imaging · 2024
Leveraging a Vision Transformer Model to Improve Diagnostic Accuracy of Cardiac Amyloidosis With Cardiac Magnetic Resonance.
СтатьяВалидационное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Cockrum Joshua, Nakashima Makiya, Ammoury Carl, Rizkallah Diane, Mauch Joseph, Lopez David, Wolinksy David, Hwang Tae Hyun, Kapadia Samir, Svensson Lars G, Grimm Richard, Hanna Mazen, Tang W H Wilson, Nguyen Christopher, Chen David, Kwon Deborah
Аннотация
BACKGROUND: Cardiac magnetic resonance (CMR) imaging is an important diagnostic tool for diagnosis of cardiac amyloidosis (CA). However, discrimination of CA from other etiologies of myocardial disease can be challenging.
OBJECTIVES: The aim of this study was to develop and rigorously validate a deep learning (DL) algorithm to aid in the discrimination of CA using cine and late gadolinium enhancement CMR imaging.
METHODS: A DL model using a retrospective cohort of 807 patients who were referred for CMR for suspicion of infiltrative disease or hypertrophic cardiomyopathy (HCM) was developed. Confirmed definitive diagnosis was as follows: 252 patients with CA, 290 patients with HCM, and 265 with neither CA or HCM (other). This cohort was split 70/30 into training and test sets. A vision transformer (ViT) model was trained primarily to identify CA. The model was validated in an external cohort of 157 patients also referred for CMR for suspicion of infiltrative disease or HCM (51 CA, 49 HCM, and 57 other).
RESULTS: The ViT model achieved a diagnostic accuracy (84.1%) and an area under the curve of 0.954 in the internal testing data set. The ViT model further demonstrated an accuracy of 82.8% and an area under the curve of 0.957 in the external testing set. The ViT model achieved an accuracy of 90% (n = 55 of 61), among studies with clinical reports with moderate/high confidence diagnosis of CA, and 61.1% (n = 22 of 36) among studies with reported uncertain, missing, or incorrect diagnosis of CA in the internal cohort. DL accuracy of this cohort increased to 79.1% when studies with poor image quality, dual pathologies, or ambiguity of clinically significant CA diagnosis were removed.
CONCLUSIONS: A ViT model using only cine and late gadolinium enhancement CMR images can achieve high accuracy in differentiating CA from other underlying etiologies of suspected cardiomyopathy, especially in cases when reported human diagnostic confidence was uncertain in both a large single state health system and in an external CA cohort.
OBJECTIVES: The aim of this study was to develop and rigorously validate a deep learning (DL) algorithm to aid in the discrimination of CA using cine and late gadolinium enhancement CMR imaging.
METHODS: A DL model using a retrospective cohort of 807 patients who were referred for CMR for suspicion of infiltrative disease or hypertrophic cardiomyopathy (HCM) was developed. Confirmed definitive diagnosis was as follows: 252 patients with CA, 290 patients with HCM, and 265 with neither CA or HCM (other). This cohort was split 70/30 into training and test sets. A vision transformer (ViT) model was trained primarily to identify CA. The model was validated in an external cohort of 157 patients also referred for CMR for suspicion of infiltrative disease or HCM (51 CA, 49 HCM, and 57 other).
RESULTS: The ViT model achieved a diagnostic accuracy (84.1%) and an area under the curve of 0.954 in the internal testing data set. The ViT model further demonstrated an accuracy of 82.8% and an area under the curve of 0.957 in the external testing set. The ViT model achieved an accuracy of 90% (n = 55 of 61), among studies with clinical reports with moderate/high confidence diagnosis of CA, and 61.1% (n = 22 of 36) among studies with reported uncertain, missing, or incorrect diagnosis of CA in the internal cohort. DL accuracy of this cohort increased to 79.1% when studies with poor image quality, dual pathologies, or ambiguity of clinically significant CA diagnosis were removed.
CONCLUSIONS: A ViT model using only cine and late gadolinium enhancement CMR images can achieve high accuracy in differentiating CA from other underlying etiologies of suspected cardiomyopathy, especially in cases when reported human diagnostic confidence was uncertain in both a large single state health system and in an external CA cohort.
Предметные рубрики MeSH
HumansRetrospective StudiesPredictive Value of TestsMaleFemaleCardiomyopathiesMiddle AgedMagnetic Resonance Imaging, CineReproducibility of ResultsAmyloidosisAgedDeep LearningImage Interpretation, Computer-AssistedContrast MediaDiagnosis, DifferentialCardiomyopathy, HypertrophicDecision Support TechniquesMyocardium