DOI 10.1007/s00540-023-03256-7

Медицинская библиотека · Journal of anesthesia · 2023

Stroke volume variation and dynamic arterial elastance predict fluid responsiveness even in thoracoscopic esophagectomy: a prospective observational study.

Hikasa Yukiko, Suzuki Satoshi, Tanabe Shunsuke, Noma Kazuhiro, Shirakawa Yasuhiro, Fujiwara Toshiyoshi, Morimatsu Hiroshi

Наблюдательное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: It remains unknown whether stroke volume variation (SVV), pulse pressure variation (PPV), and dynamic arterial elastance (Eadyn) are suitable for monitoring fluid management during thoracoscopic esophagectomy (TE) in the prone position with one-lung ventilation and artificial pneumothorax. Our study aimed to evaluate the accuracy of SVV, PVV, and Eadyn in predicting the fluid responsiveness in these patients.

METHODS

We recruited 24 patients who had undergone TE. Patients with a mean arterial blood pressure ≤ 65 mmHg received a 200-ml bolus of 6% hydroxyethyl starch over 10 min. Fluid responders showed the stroke volume index ≥ 15% 5 min after the fluid bolus. Receiver operating characteristic (ROC) curves were generated and area under the ROC curve (AUROC) was calculated.

RESULTS

We obtained 61 fluid bolus data points, of which 20 were responders and 41 were non-responders. The median SVV before the fluid bolus in responders was significantly higher than that in non-responders (18% [interquartile range (IQR) 13-21] vs. 12% [IQR 8-15], P = 0.001). Eadyn was significantly lower in responders than in non-responders (0.55 [IQR 0.45-0.78] vs. 0.91 [IQR 0.67-1.00], P < 0.001). There was no difference in the PPV between the groups. The AUROC was 0.76 for SVV (95% confidence interval [CI] 0.62-0.89, P = 0.001), 0.56 for PPV (95% CI 0.41-0.71, P = 0.44), and 0.82 for Eadyn (95% CI 0.69-0.95, P < 0.001).

CONCLUSIONS

SVV and Eadyn are reliable parameters for predicting fluid responsiveness in patients undergoing TE.

Для цитирования: Hikasa Yukiko, Suzuki Satoshi, Tanabe Shunsuke, Noma Kazuhiro, Shirakawa Yasuhiro, Fujiwara Toshiyoshi, Morimatsu Hiroshi. Stroke volume variation and dynamic arterial elastance predict fluid responsiveness even in thoracoscopic esophagectomy: a prospective observational study.. Journal of anesthesia. 2023. DOI: 10.1007/s00540-023-03256-7.