MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jce.15667

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2022

The high-density grid catheter: A safe adjunctive tool in pediatric and complex congenital heart disease patients.

Newlon Claire, Asaki S Yukiko, Pilcher Thomas A, Ou Zhining, Etheridge Susan P, Niu Mary C

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

INTRODUCTION

The safety and utility of the Advisor™ High-Density Grid mapping catheter (HDGC) in children and congenital heart disease (CHD) patients are not well described.

METHODS

A single-center retrospective cohort study of pediatric and CHD patients undergoing electrophysiology study and ablation to determine the effect of HDGC use on outcomes including complications, fluoroscopy use, procedure duration, acute ablation success, and arrhythmia recurrence.

RESULTS

HDGC was used in 74/261 (28.3%) cases. HDGC subjects differed by median age (17 vs. 13 years; p < 0.001), weight (68 vs. 50 kg; p < 0.001), and prevalence of significant CHD (42% vs. 3%; p < 0.001). Arrhythmia substrates were dissimilar: HGDC cases had higher frequencies of intra-atrial re-entrant tachycardia (25.7% vs. 0.5%), atrial flutter (8.1% vs. 1.1%), ectopic atrial tachycardia (13.5% vs. 3.7%), and premature ventricular contractions (9.5% vs. 0.5%), and lower incidences of atrioventricular re-entrant tachycardia (16.2% vs. 46.1%). Complications were rare (n = 5, 1.9%) with no significant difference between groups (p = 1.00). Procedure duration-but not fluoroscopy exposure-was significantly longer in HDGC cases (median 256 vs. 216 min, p < 0.001). Acute success was lower (93.2% vs. 99.4%; p = 0.01) and recurrences higher (13.2% vs. 3.8%; p = 0.016) in HDGC compared to non-HDGC cases.

CONCLUSION

HDGC use in children and CHD patients is safe and not associated with higher complication rates. The lower acute success and higher recurrence rates in HDGC cases likely reflect a bias toward HDGC use in more complex arrhythmia substrates rather than less favorable ablation outcomes.

Для цитирования: Newlon Claire, Asaki S Yukiko, Pilcher Thomas A, Ou Zhining, Etheridge Susan P, Niu Mary C. The high-density grid catheter: A safe adjunctive tool in pediatric and complex congenital heart disease patients.. Journal of cardiovascular electrophysiology. 2022. DOI: 10.1111/jce.15667.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.