m+Medelevator.RU
← Поиск публикаций
The British journal of ophthalmology · 2024

Deep learning-based image quality assessment for optical coherence tomography macular scans: a multicentre study.

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Tang Ziqi, Wang Xi, Ran An Ran, Yang Dawei, Ling Anni, Yam Jason C, Zhang Xiujuan, Szeto Simon K H, Chan Jason, Wong Cherie Y K, Hui Vivian W K, Chan Carmen K M, Wong Tien Yin, Cheng Ching-Yu, Sabanayagam Charumathi, Tham Yih Chung, Liew Gerald, Anantharaman Giridhar, Raman Rajiv, Cai Yu, Che Haoxuan, Luo Luyang, Liu Quande, Wong Yiu Lun, Ngai Amanda K Y, Yuen Vincent L, Kei Nelson, Lai Timothy Y Y, Chen Hao, Tham Clement C, Heng Pheng-Ann, Cheung Carol Y

Аннотация

AIMS: To develop and externally test deep learning (DL) models for assessing the image quality of three-dimensional (3D) macular scans from Cirrus and Spectralis optical coherence tomography devices.

METHODS: We retrospectively collected two data sets including 2277 Cirrus 3D scans and 1557 Spectralis 3D scans, respectively, for training (70%), fine-tuning (10%) and internal validation (20%) from electronic medical and research records at The Chinese University of Hong Kong Eye Centre and the Hong Kong Eye Hospital. Scans with various eye diseases (eg, diabetic macular oedema, age-related macular degeneration, polypoidal choroidal vasculopathy and pathological myopia), and scans of normal eyes from adults and children were included. Two graders labelled each 3D scan as gradable or ungradable, according to standardised criteria. We used a 3D version of the residual network (ResNet)-18 for Cirrus 3D scans and a multiple-instance learning pipline with ResNet-18 for Spectralis 3D scans. Two deep learning (DL) models were further tested via three unseen Cirrus data sets from Singapore and five unseen Spectralis data sets from India, Australia and Hong Kong, respectively.

RESULTS: In the internal validation, the models achieved the area under curves (AUCs) of 0.930 (0.885-0.976) and 0.906 (0.863-0.948) for assessing the Cirrus 3D scans and Spectralis 3D scans, respectively. In the external testing, the models showed robust performance with AUCs ranging from 0.832 (0.730-0.934) to 0.930 (0.906-0.953) and 0.891 (0.836-0.945) to 0.962 (0.918-1.000), respectively.

CONCLUSIONS: Our models could be used for filtering out ungradable 3D scans and further incorporated with a disease-detection DL model, allowing a fully automated eye disease detection workflow.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты