BACKGROUND

The basophil activation test (BAT) is an effective diagnostic tool in mold allergy, which is still not sufficiently known.

OBJECTIVES

The aim of our study was to assess the degree of annexin V binding to the surface of the basophil cell membrane after stimulation with anti-immunoglobulin E (anti-IgE) and Alternaria alternata allergenic extract.

MATERIAL AND

METHODS

Alternaria alternata allergic patients (n = 32) and healthy volunteers (n = 33) were evaluated using skin prick tests (SPT), quantification of specific IgE (sIgE) and the BAT. Basophil activation was detected as a percentage degree of annexin V binding to the surface of the basophil cell membrane.

RESULTS

Receiver operating characteristic (ROC) curve analysis yielded a threshold value of 4.95% of activated basophils when the tested group and control group were studied, with a sensitivity and specificity of 100% (area under curve [AUC] = 1; p = 0.00000) for 100 SBU/mL Alternaria alternata allergen extract. The threshold value was 10.28% with a sensitivity of 93.8% and specificity of 100% (AUC = 0.98958; p = 0.00000) for 10 SBU/mL mold extract, and 9.37% with a sensitivity of 90.3% and specificity of 100% (AUC = 0.96307; p = 0.00000) for 1 SBU/mL Alternaria alternata allergen extract. The method was least efficacious in antiIgE stimulation, where the threshold value was 5.48% with a sensitivity of 90.6% and specificity of 30.3% (AUC = 0.46780; p = 0.67039).

CONCLUSIONS

The BAT with annexin V and sIgE measurement against Alternaria alternata increase the capability of a diagnostic laboratory for detecting mold sensitization. Both methods may certainly replace SPT, which are currently routinely used in allergy diagnosis. Annexin V may be considered a new basophil activation marker with an efficacy comparable to that of CD63 or CD203c.

Для цитирования: Królewicz Emilia, Gomułka Krzysztof, Wolańczyk-Mędrala Anna, Mędrala Wojciech, Barg Wojciech, Kustrzeba-Wójcicka Irena. The diagnostic usefulness of the basophil activation test (BAT) with annexin V in an allergy to Alternaria alternata.. Advances in clinical and experimental medicine : official organ Wroclaw Medical University. 2018. DOI: 10.17219/acem/78563.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.