The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2017
Lung clearance index is sensitive to small airway disease in pediatric lung transplant recipients.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Kao Julia E, Zirbes Jacquelyn M, Conrad Carol K, Milla Carlos E
Аннотация
BACKGROUND: The principal obstacle to long-term survival after lung transplant is chronic lung allograft dysfunction (CLAD), which primarily affects the small airways. After transplant, patients are monitored with spirometry, which is a generally insensitive detector of small airways obstruction. The lung clearance index (LCI) is a measure obtained during multiple breath washout (MBW) maneuvers. We hypothesized that among lung allograft recipients, LCI would detect small airways disease not detected with spirometry.
METHODS: This study enrolled 15 patients, 5 of whom already had a diagnosis of CLAD. We added MBW as an additional index of peripheral airway function to the established post-transplant routine care protocol.
RESULTS: Of trials, 87.9% yielded valid measurements, and single maneuvers were 2-8 minutes. LCI did not yield any false-negative findings-no patients were considered obstructed by forced expiratory volume in 1 second (FEV1) but normal by LCI. At enrollment, 6 patients without CLAD had an elevated LCI, and 4 progressed to CLAD. Only 2 of these 4 patients would have been identified by a decrease in FEV1.
CONCLUSIONS: LCI identified lung allograft dysfunction in more patients than the use of standardized spirometric measures, including patients with abnormal FEV1. These data suggest that LCI from MBW may be a more sensitive means to detect allograft peripheral airway disease than standard methods for measurement of small airways function.
METHODS: This study enrolled 15 patients, 5 of whom already had a diagnosis of CLAD. We added MBW as an additional index of peripheral airway function to the established post-transplant routine care protocol.
RESULTS: Of trials, 87.9% yielded valid measurements, and single maneuvers were 2-8 minutes. LCI did not yield any false-negative findings-no patients were considered obstructed by forced expiratory volume in 1 second (FEV1) but normal by LCI. At enrollment, 6 patients without CLAD had an elevated LCI, and 4 progressed to CLAD. Only 2 of these 4 patients would have been identified by a decrease in FEV1.
CONCLUSIONS: LCI identified lung allograft dysfunction in more patients than the use of standardized spirometric measures, including patients with abnormal FEV1. These data suggest that LCI from MBW may be a more sensitive means to detect allograft peripheral airway disease than standard methods for measurement of small airways function.
Предметные рубрики MeSH
AdolescentAllograftsBronchiolesBronchospirometryChildChild, PreschoolCohort StudiesCystic FibrosisFemaleForced Expiratory VolumeGraft RejectionGraft SurvivalHumansHypertension, PulmonaryLinear ModelsLung TransplantationMalePediatricsPredictive Value of TestsPrimary Graft DysfunctionPrognosisProspective StudiesRisk AssessmentSurvival RateTransplant RecipientsTreatment Outcome